A biomedical device uses a shunt resistor to measure blood-pump current non-invasively

PHYSICS · Multi-part · A Level · Physics · Electricity · Electricity

Problem

A biomedical device uses a shunt resistor to measure blood-pump current non-invasively. The device’s power unit supplies a steady 2.4 A2.4\,\text{A} current that reaches a junction J and splits into two parallel paths before returning to the supply. Path A contains the implanted pump (modeled as a 3.0 Ω3.0\,\Omega resistor). Path B contains the precision shunt resistor RsR_s in series with a monitoring circuit whose internal resistance is negligible. A medical technician wants the monitoring circuit to read exactly 0.40 A0.40\,\text{A} through the shunt. (a) Calculate the current that must flow through the pump when the monitor reads the desired 0.40 A0.40\,\text{A}. (b) Determine the numerical value of the shunt resistance RsR_s that will achieve this current distribution. (c) Compute the electrical power delivered to the pump under these operating conditions.