A pulse-echo test on an aluminium alloy block thick (density ) gives longitudinal…

PHYSICS · Multi-part · Fermi University Physics · Fluids & Continuum Physics · Solid continuum mechanics and complex fluids · Solid continuum mechanics and complex fluids

Bending, Ringing, Breaking and Flowing, Ch Elastic waves in a solid and at its surface

Problem

A pulse-echo test on an aluminium alloy block 20.0 mm20.0\,\mathrm{mm} thick (density 2700 kg m−32700\,\mathrm{kg\,m^{-3}}) gives longitudinal echoes every 6.486 μs6.486\,\mathrm{\mu s} and shear echoes every 12.88 μs12.88\,\mathrm{\mu s}, each timed to ±0.01 μs\pm0.01\,\mathrm{\mu s}. A slow tensile test on the same alloy gave E=69.0 GPaE=69.0\,\mathrm{GPa}. ((a)) Find EE and ν\nu from the echoes, and the fraction by which the ultrasonic EE exceeds the tensile value. ((b)) Estimate the adiabatic correction ΔE/E\Delta E/E for this alloy at T=293 KT=293\,\mathrm{K}, with α=23×10−6 K−1\alpha=23\times10^{-6}\,\mathrm{K^{-1}} and cp=900 J kg−1 K−1c_p=900\,\mathrm{J\,kg^{-1}\,K^{-1}}. ((c)) Shift each echo time by 0.01 μs0.01\,\mathrm{\mu s} in the direction that changes EE most, and find the largest fractional error in EE the timing allows. Is the difference found in (a) a timing error, or the adiabatic correction?