A pulse-echo test on an aluminium alloy block thick (density ) gives longitudinal…
PHYSICS · Multi-part · Fermi University Physics · Fluids & Continuum Physics · Solid continuum mechanics and complex fluids · Solid continuum mechanics and complex fluids
Bending, Ringing, Breaking and Flowing, Ch Elastic waves in a solid and at its surface
Problem
A pulse-echo test on an aluminium alloy block 20.0mm thick (density 2700kgm−3) gives longitudinal echoes every 6.486μs and shear echoes every 12.88μs, each timed to ±0.01μs. A slow tensile test on the same alloy gave E=69.0GPa.
((a)) Find E and ν from the echoes, and the fraction by which the ultrasonic E exceeds the tensile value.
((b)) Estimate the adiabatic correction ΔE/E for this alloy at T=293K, with α=23×10−6K−1 and cp=900Jkg−1K−1.
((c)) Shift each echo time by 0.01μs in the direction that changes E most, and find the largest fractional error in E the timing allows. Is the difference found in (a) a timing error, or the adiabatic correction?