A strain-gauge conditioning board carries a Sallen-Key low-pass filter ahead of its…
PHYSICS · Multi-part · Fermi University Physics · Electronics, Instrumentation & Communication · Feedback, operational amplifiers and analogue signal processing · Feedback, operational amplifiers and analogue signal processing
Electronics for Measurement, Ch Active filters, oscillators and timers
Problem
A strain-gauge conditioning board carries a Sallen-Key low-pass filter ahead of its analogue-to-digital converter, and a monostable timer that produces a fixed-width gate for a pulse counter. Both circuits use an ideal operational amplifier or an ideal comparator, with gain-bandwidth and switching speed ample at these frequencies.
((a)) The equal-component Sallen-Key low-pass is designed for f0=2.0kHz and damping Q=1.00. Using C=4.7nF (E12), find the R the design equation asks for, round to the nearest E12 preferred value, and state the corner the filter will actually show.
((b)) Find the gain K that Q=1.00 requires, and choose a preferred-value feedback resistor pair from the E12 series that realises it exactly. State the Q this pair actually gives.
((c)) The monostable timer, built from an ideal comparator with positive-feedback fraction β=0.5 and a diode that holds its capacitor at 0V between pulses, has output pulse width Tmono=RCln(1−β1). A pulse width of 2.00ms is wanted. Using C=100nF (E12), find the required R, round to the nearest E12 value, and state the pulse width the timer will actually produce.