A strain-logger uses a 10-bit analogue-to-digital converter with a full-scale…
PHYSICS · Multi-part · Fermi University Physics · Electronics, Instrumentation & Communication · Digital electronics, embedded systems and data acquisition · Digital electronics, embedded systems and data acquisition
Electronics for Measurement, Ch Sampling, quantisation and the acquisition chain
Problem
A strain-logger uses a 10-bit analogue-to-digital converter with a full-scale reference of VFS=5.00V and a busy (non-static) input signal. Calculate
((a)) the quantisation step Δ,
((b)) the rms quantisation noise, and
((c)) the full-scale signal-to-noise ratio in decibels.