A strain-gauge signal of interest lies between and and is logged with a -bit…
PHYSICS · Multi-part · Fermi University Physics · Electronics, Instrumentation & Communication · Digital electronics, embedded systems and data acquisition · Digital electronics, embedded systems and data acquisition
Electronics for Measurement, Ch Sampling, quantisation and the acquisition chain
Problem
A strain-gauge signal of interest lies between 0 and 400Hz and is logged with a 10-bit converter sampling at fs=1kHz, with no anti-alias filter fitted. The bench supply couples in an interference tone at 950Hz. A colleague argues: "950Hz is well above our 400Hz band of interest, so it cannot affect our reading; and if the record still looks noisy, we should simply fit a 16-bit converter instead."
((a)) Find the frequency at which the 950Hz interference actually appears in the logged record.
((b)) State whether fitting a 16-bit converter would remove this error, and why.