A compressed-air store is designed for rather than

PHYSICS · Multi-part · Fermi University Physics · Earth, Climate & Energy Physics · Energy systems, storage and demand · Energy systems, storage and demand

Energy from Physics, Ch Storing energy: cells, rotors, air, heat and hydrogen

Problem

A compressed-air store is designed for 40 bar40\,\mathrm{bar} rather than 70 bar70\,\mathrm{bar}, filled from p0=1 barp_0 = 1\,\mathrm{bar} with air taken in at 300 K300\,\mathrm{K}. ((a)) Find the isothermal work stored per cubic metre of cavern for a rigid cavern and for a constant-pressure cavern at 40 bar40\,\mathrm{bar}. ((b)) Find the temperature at which the air would leave a single adiabatic compression stage to 40 bar40\,\mathrm{bar}, taking γ=1.4\gamma = 1.4. ((c)) By what factor does raising the storage pressure from 4040 to 70 bar70\,\mathrm{bar} raise the rigid cavern's stored energy per cubic metre?