A thermocouple with its reference junction at has a Seebeck coefficient fitted over by
PHYSICS · Multi-part · Fermi University Physics · Mathematical Methods for Physics · Numerical and computational mathematics · Numerical and computational mathematics
Error, Chance and the Machine, Ch Integration: error expansions, Gauss rules and adaptivity
Problem
A thermocouple with its reference junction at 0∘C has a Seebeck coefficient fitted over 0≤T≤1000∘C by S(T)=40/(1+T/800)μVK−1, and its output voltage is E(T)=∫0TS(T′)dT′. The closed form E(T)=32000ln(1+T/800)μV may be used as the reference value in checks, but the rules below may use only values of S. Errors are measured as value minus exact value.
((a)) Compute E(500∘C) with the three-node Gauss-Legendre rule and with the three-node Clenshaw-Curtis rule (nodes cos(kπ/2), mapped to [0,500]), and give the error of each.
((b)) Let Q1 be each value from part (a) and Q2 the sum of the same rule on [0,250] and [250,500]. Estimate the error of Q2 for each rule a posteriori, using the divisor that its local error requires. Compare each estimate with the true error of Q2, count the function values needed for Q1 and Q2 together in each rule, and state the assumption behind the estimates.
((c)) Tabulate E at the five Chebyshev points Tj=500(1+cos(jπ/4))∘C, j=0,…,4, and evaluate the barycentric interpolant at 300∘C. Give its error.
((d)) A measurement gives E=12000μV. Solve E(T)=12000μV by Newton's method from T0=400∘C, using S as the derivative of E. Give T1 and T2, and the order observed from the errors of T0, T1 and T2.
((e)) The voltage is uncertain by ±5μV. Find the resulting uncertainty in T from the sensitivity of the inversion, and say which of the errors in parts (a) and (c) can be neglected beside it.