A horizontal Venturi meter is fitted in a water main

PHYSICS · Subjective · Fermi University Physics · Fluids & Continuum Physics · Kinematics, conservation laws and ideal flow · Kinematics, conservation laws and ideal flow

Fluids and Continuum Physics, Ch Bernoulli at work: Venturi meters, Pitot tubes and lift

Problem

A horizontal Venturi meter is fitted in a water main. The full-bore diameter is 2020 cm and the throat diameter is 1010 cm. Two manometer legs, one tapped into the full bore and one into the throat, show that the pressure at the throat is 1515 kPa below the pressure in the full bore. Take the water to be incompressible with density 10001000 kg m−3^{-3}, and treat the flow as steady and inviscid so that Bernoulli's theorem may be applied along the streamline running down the axis of the meter, which is horizontal. Find the volume flow rate through the main, in litres per second.