A DC amplifier used to measure a slowly varying voltage has a noise spectral density
PHYSICS · Multi-part · Fermi University Physics · Scientific Practice & Experimental Methods · Uncertainty in measurement · Designing and running experiments
Measurement and Method, Ch Designing the measurement: noise, averaging, null and differential methods
Problem
A DC amplifier used to measure a slowly varying voltage has a noise spectral density en=50nV/Hz. Before its case has settled to a steady temperature its zero drifts at a rate D=0.20μVs−1. Each measurement is the difference between two averages, each of readings taken for a time t, and the total standard uncertainty on that difference is u(t)=ten2+(Dt)2.
((a)) Find the optimum averaging time topt and the resulting minimum uncertainty u(topt).
((b)) A thermally regulated enclosure is fitted, cutting the drift by a factor of 8 to D′=25nVs−1. Find the new optimum averaging time topt′ and the new minimum uncertainty u(topt′).
((c)) State, as a ratio, how much longer the new averaging takes and how much the minimum uncertainty improves, and comment on whether these two ratios are equal.