A diffuse reflectance calibration panel used to check a spectrometer behaves as a…

PHYSICS · Multi-part · Fermi University Physics · Optics & Photonics · Geometrical optics and imaging · Geometrical optics and imaging

Optics and Photonics, Ch Radiometry and photometry

Problem

A diffuse reflectance calibration panel used to check a spectrometer behaves as a Lambertian surface of radiance L=50L = 50 W m−2^{-2} sr−1^{-1}, the same in every direction above it. A relay lens, air on both sides (n=1n=1), collects a narrow beam from the panel whose marginal ray has height h1=4h_1 = 4 mm and half-angle u1=0.03u_1 = 0.03 rad before the lens, and forms an image with transverse magnification M=6M = 6. ((a)) Starting from the hemisphere integral Me=∫02π∫0π/2Lcos⁡θsin⁡θ dθ dϕ,M_e = \int_0^{2\pi}\int_0^{\pi/2} L\cos\theta\sin\theta\,d\theta\,d\phi, derive Me=πLM_e = \pi L and hence find the radiant exitance of the panel. ((b)) Using the Lagrange invariant H=nhu\mathcal H = nhu from Chapter 1 (preserved because every elementary ray-transfer matrix has determinant 1) and the etendue of a narrow circular beam, G=n2AΩ=π2H2G = n^2A\Omega = \pi^2\mathcal H^2, derive that a lossless lens leaves the beam's etendue unchanged. Find the marginal ray's half-angle u2u_2 after the lens and confirm numerically that the etendue is the same on both sides.