(a) A fusion device measures the line-averaged electron density along a chord of…

PHYSICS · Subjective · Fermi University Physics · Plasma Physics · Laboratory, industrial and space plasmas · Laboratory, industrial and space plasmas

Plasma Physics, Ch Plasma oscillations and light in an unmagnetised plasma

Problem

(a) A fusion device measures the line-averaged electron density along a chord of length L=3.0 mL=3.0\,\mathrm m using a λ=119 μm\lambda=119\,\mu\mathrm m methanol-laser interferometer. The measured phase shift relative to vacuum is Δϕ=50.3 rad\Delta\phi=50.3\,\mathrm{rad}. Using Δϕ=reλ∫ne dl\Delta\phi=r_e\lambda\int n_e\,\mathrm dl with the classical electron radius re=2.82×10−15 mr_e=2.82\times10^{-15}\,\mathrm m, and taking the density uniform along the chord, find the line-averaged electron density nen_e. Then compute the critical density nc=1.1×1027λμm−2 m−3n_c=1.1\times10^{27}\lambda_{\mu\mathrm m}^{-2}\,\mathrm m^{-3} for this wavelength and confirm ne≪ncn_e\ll n_c, so the small-parameter expansion behind the phase-shift formula is valid. (b) A pulsar is timed at two frequencies, f1=300 MHzf_1=300\,\mathrm{MHz} and f2=1.4 GHzf_2=1.4\,\mathrm{GHz}, and the pulse at f1f_1 arrives Δt=1.54 s\Delta t=1.54\,\mathrm s after the pulse at f2f_2. Using Δt=4.15 ms×DM[pc cm−3]×[(f1/GHz)−2−(f2/GHz)−2]\Delta t=4.15\,\mathrm{ms}\times\mathrm{DM[pc\,cm^{-3}]}\times\left[(f_1/\mathrm{GHz})^{-2}-(f_2/\mathrm{GHz})^{-2}\right], find the dispersion measure DM. Then, assuming a mean interstellar electron density of 0.03 cm−30.03\,\mathrm{cm^{-3}} along the line of sight, estimate the pulsar's distance in parsecs.