A sample of unknown composition is checked for sodium by thermal-neutron activation…

PHYSICS · Multi-part · Fermi University Physics · Nuclear Physics · Radioactivity and decay modes · Radiation interactions, detection and dosimetry

The Nucleus Resolved, Ch What it is used for: medicine, dating and analysis

Problem

A sample of unknown composition is checked for sodium by thermal-neutron activation analysis, using 23Na(n,γ)24Na^{23}\mathrm{Na}(n,\gamma)^{24}\mathrm{Na}, thermal cross section σ=0.53 b\sigma = 0.53\,\mathrm{b}, 24Na^{24}\mathrm{Na} half-life 15.0 h15.0\,\mathrm{h}, decaying with a 1368.5 keV1368.5\,\mathrm{keV} gamma ray emitted in essentially every decay. The sample is irradiated for 1.00 h1.00\,\mathrm{h} in a thermal flux ϕ=1.0×1013 cm−2 s−1\phi = 1.0\times10^{13}\,\mathrm{cm^{-2}\,s^{-1}}, then counted immediately for 10.0 min10.0\,\mathrm{min} in a detector of 5.0 %5.0\,\% full-energy efficiency at that line. In that counting window the background under the peak is measured to be 900900 counts. ((a)) Using the rule that a signal is detectable once it exceeds three standard deviations of the background (a simpler and looser rule than Chapter 10's detection limit LD=2.71+4.65BL_D = 2.71 + 4.65\sqrt{B}), find the minimum number of counts under the peak that would count as a detection. ((b)) Neglecting decay during the 10.0 min10.0\,\mathrm{min} count (it is small compared with the 15.0 h15.0\,\mathrm{h} half-life) and neglecting any delay between the end of irradiation and the start of counting, find the minimum detectable mass of sodium.