A long-exposure exoplanet-transit photometer is fed by a fibre of core diameter and…
PHYSICS · Multi-part · Fermi University Physics · Optics & Photonics · Geometrical optics and imaging · Photodetection, photonic sources and quantum optics
What an Instrument Can See, Ch Radiance, etendue and a throughput budget that is spent
Problem
A long-exposure exoplanet-transit photometer is fed by a fibre of core diameter 8μm and numerical aperture NA=0.12.
((a)) Find the fibre's etendue Ξ=πANA2.
((b)) The star gives a signal of only 0.01e−s−1. The detector has dark current 1.0e−s−1 and read noise 2e− (rms, once per exposure), and the integration time is 100s. Find the signal-to-noise ratio and identify the dominant noise term.
((c)) An indicator LED at 620nm used to flag the shutter state radiates 50mW. Using V(620nm)=0.381 and Km=683lmW−1, find its luminous flux.