Quantum State Tomography of Light

The Wigner function is the object this article learns to photograph. Quantum optics hands us a full phase-space portrait of a light mode — a quasiprobability landscape W(x,p)W(x,p) equivalent to the density operator ρ^\hat\rho and, uniquely among classical-looking distributions, allowed to go negative. Quantum mechanics forbids the obvious way to measure it: x^\hat x and p^\hat p do not commute, so no single copy can report both coordinates of a phase-space point. Quantum state tomography resolves the tension without beating the uncertainty relation — it spends copies. Each prepared pulse is sacrificed to one measurement of one rotated quadrature, and the ensemble of outcomes, gathered over every angle, rebuilds the whole landscape. The instrument that supplies those angles is balanced homodyne detection. The signal beats against a bright coherent local oscillator of phase θ\theta on a 50:50 beam splitter, and the difference of the two photocurrents reads out the rotated quadrature x^θ=x^cos⁡θ+p^sin⁡θ\hat x_\theta=\hat x\cos\theta+\hat p\sin\theta. Sweep θ\theta across a half-circle and the collected histograms pr(x,θ)\mathrm{pr}(x,\theta) turn out to be exactly the projections of WW along every direction — the same marginals a CT scanner records imaging a patient from all sides. Vogel and Risken saw this in 1989; Smithey, Beck, Raymer and Faridani turned it into a working camera for squeezed light in 1993. What began as an X-ray-style inversion is now a disciplined statistical estimation problem, and the negativity it exposes is the field's cleanest certificate of the genuinely quantum.

Key takeaways
  • Quantum state tomography reconstructs the complete quantum state of a light mode — its density matrix ρ^\hat\rho, equivalently its Wigner function W(x,p)W(x,p) — from an ensemble of measurements on identically prepared copies.
  • Balanced homodyne detection at local-oscillator phase θ\theta measures the rotated quadrature x^θ\hat x_\theta; the histograms pr(x,θ)\mathrm{pr}(x,\theta) are the marginal (projection) distributions of WW.
  • Those marginals over all θ∈[0,π)\theta\in[0,\pi) are Radon projections, so the inverse Radon transform — filtered back-projection, borrowed from medical CT — returns W(x,p)W(x,p); this is optical homodyne tomography.
  • Raw back-projection is noisy and can produce unphysical density matrices, so modern reconstruction uses maximum-likelihood or Bayesian estimation constrained to ρ^≥0\hat\rho\ge0, Tr ρ^=1\mathrm{Tr}\,\hat\rho=1.
  • Detection loss η<1\eta<1 convolves the sampled Wigner function with a Gaussian of variance (1−η)/(2η)(1-\eta)/(2\eta) per quadrature; for η≤12\eta\le\tfrac12 any state's tomogram is provably non-negative, so certifying negativity demands η>12\eta>\tfrac12.
  • Key idea: the quadrature histograms pr(x,θ)\mathrm{pr}(x,\theta) that homodyne detection collects over all local-oscillator phases θ\theta are the Radon projections of the Wigner function; inverting the Radon transform — or, better, maximizing the likelihood of the data over physical states — recovers W(x,p)W(x,p) and the full density matrix ρ^\hat\rho.
The core insight

The homodyne quadrature histograms pr(x,θ)\mathrm{pr}(x,\theta), gathered over all local-oscillator phases θ\theta, are the Radon projections of the Wigner function; inverting the Radon transform (or maximizing the data likelihood over the physical set ρ^≥0\hat\rho\ge0, Tr ρ^=1\mathrm{Tr}\,\hat\rho=1) recovers W(x,p)W(x,p) and hence ρ^\hat\rho.

Where this lives today

Homodyne tomography is now standard laboratory instrumentation, and its most visible payoff is characterizing squeezed light for gravitational-wave detection: the squeezed vacuum injected into Advanced LIGO and Advanced Virgo to push noise below the shot-noise limit is validated by the very noise-ellipse reconstruction Smithey and Raymer first demonstrated. The same technique benchmarks single-photon and Fock-state sources — the depth of the reconstructed Wigner dip, after honest efficiency correction, is the accepted figure of merit for source purity — and verifies the two-mode entanglement of continuous-variable resources for teleportation and quantum key distribution. Where the light is not a propagating beam, its phase-space cousin takes over. In circuit and cavity QED the displaced-parity method of equation (6) reigns: a superconducting qubit or Rydberg atom displaces the field by a controlled α\alpha and reads its photon-number parity through a Ramsey sequence, mapping W(α)W(\alpha) point by point with no inversion. This is how the celebrated Schrödinger-cat states of microwave fields were imaged, their fringes and negativities laid bare, and how error-correctable bosonic qubits are now diagnosed. Across both platforms the deliverable is what Fano asked for in 1957 — a complete, physical estimate of the state — with Wigner negativity as the cleanest, assumption-light certificate that the light is genuinely quantum.

The physical picture

Picture the Wigner function as a low relief over the phase plane (x,p)(x,p) — a mound for a coherent state, a tilted ellipse for squeezed light, and, for genuinely quantum states, a surface that dips below zero where no classical probability could. A homodyne measurement at phase θ\theta does not sample a point of this relief; it records the shadow the relief casts onto a screen tilted at angle θ\theta — the marginal pr(x,θ)=∫W dpθ\mathrm{pr}(x,\theta)=\int W\,\mathrm{d}p_\theta, the integral of WW along the line perpendicular to θ\theta. Rotate the local oscillator and you illuminate the same object from a new side; a 2D shape is fixed once you know its shadows from every direction. This is not a loose analogy — it is the identical mathematics. The local-oscillator phase is the CT gantry angle, the quadrature histogram the X-ray projection, and the inverse Radon transform the same kernel a hospital scanner runs.

Figure
Homodyne tomography as computed tomography. Each local-oscillator phase θ is a gantry angle: the difference current reads the rotated quadrature x̂_θ, and its histogram pr(x,θ) is the shadow of the Wigner relief projected along direction θ. Sweeping θ from 0 to π and inverting the Radon transform rebuilds W(x,p). The vacuum disk has quadrature variance ⟨Δx̂²⟩ = 1/2, the shot-noise reference.
One local-oscillator phase θ = one CT projection of the Wigner function x p vacuum disk ⟨Δx̂²⟩ = 1/2 θ = 45° quadrature x at phase θ pr(x,θ) histogram of many homodyne outcomes

Why does no single-shot trick collapse the ensemble into one measurement? Because complementarity is not negotiable: x^\hat x and p^\hat p cannot be co-measured on one copy, so each pulse yields one number along one direction. Tomography respects this exactly — it extracts one coordinate from each of very many photons and lets statistics do the rest. The price is copies; the payoff is total, since the reconstructed WW, equivalently every density-matrix element ρmn\rho_{mn}, is the complete description of the mode. The reconstruction earns its cost by showing what nothing classical can. A Gaussian state — coherent, thermal, squeezed — has a strictly positive Wigner function whose every projection is a Gaussian, so its tomogram is a smooth blob fixed by a mean and covariance. Nonclassical states betray themselves: a single photon carves a hole through the center of phase space, a cat state stripes it with fringes, and their projections dip and wiggle in ways no product of Gaussians can imitate. The inversion resolves these into rings and troughs of negative Wigner density — the fingerprint the whole apparatus is built to expose, because no mixture of classical fields can fake it.

Figure
Radial cut of the single-photon Wigner function W(r) = (1/π)(2r² − 1) e^(−r²) with r² = x² + p². It plunges to W(0,0) = −1/π ≈ −0.318 at the origin, crosses zero at r = 1/√2 ≈ 0.707, and rises to a positive ring peaking near W ≈ 0.14 at r ≈ 1.2. Detection loss η lifts the central value to (1 − 2η)/π, so at η = 0.6 the dip is only −0.064 and at η = 0.45 it has vanished to +0.032 — negativity survives only for η greater than 1/2.
The nonclassicality signature: the single-photon Wigner dip, W(0,0) = −1/π ≈ −0.318 +0.10 0 −0.10 −0.20 −0.30 0 1 2 3 phase-space radius r = √(x² + p²) Wigner value W(r) W(0,0) = −1/π ≈ −0.318 zero at r = 0.707 positive ring, W ≈ 0.14 η = 0.6 loss: W(0,0) = (1−2η)/π = −0.064

The core equations

The starting point is the observable homodyne delivers. Rotating the local-oscillator phase θ\theta rotates the measured quadrature, so one homodyne channel accesses any linear combination of the two canonical quadratures — the tomographic ray along direction θ\theta, whose eigenvalue each shot records.

x^θ=x^cos⁡θ+p^sin⁡θ=12(a^ e−iθ+a^†eiθ)(1)\hat x_\theta = \hat x\cos\theta + \hat p\sin\theta = \tfrac{1}{\sqrt{2}}\left(\hat a\,e^{-i\theta}+\hat a^\dagger e^{i\theta}\right) \qquad (1)

where: x^,p^\hat x,\hat p — canonical quadratures with [x^,p^]=i[\hat x,\hat p]=i in the ℏ→1\hbar\to1 convention (vacuum variance 12\tfrac12); θ\theta — local-oscillator phase, the projection angle; a^,a^†\hat a,\hat a^\dagger — mode ladder operators. As θ\theta runs over [0,π)[0,\pi), x^θ\hat x_\theta sweeps every direction in the phase plane; θ\theta and θ+π\theta+\pi give the same axis with x→−xx\to-x, so a half-circle suffices. The central identity of the subject is that the probability density of homodyne outcomes at phase θ\theta is a literal geometric projection of the Wigner function. It equals the diagonal element of ρ^\hat\rho in the x^θ\hat x_\theta eigenbasis, which is WW integrated along the conjugate direction — the Radon projection a CT scanner measures.

pr(x,θ)=⟨xθ∣ρ^∣xθ⟩=∫−∞∞W(xcos⁡θ−psin⁡θ,  xsin⁡θ+pcos⁡θ) dp(2)\mathrm{pr}(x,\theta) = \langle x_\theta|\hat\rho|x_\theta\rangle = \int_{-\infty}^{\infty} W(x\cos\theta - p\sin\theta,\; x\sin\theta + p\cos\theta)\,\mathrm{d}p \qquad (2)

where: pr(x,θ)\mathrm{pr}(x,\theta) — probability density of outcome xx at phase θ\theta; ∣xθ⟩|x_\theta\rangle — eigenstate of x^θ\hat x_\theta; WW — Wigner function. The identity holds because the projector ∣xθ⟩⟨xθ∣|x_\theta\rangle\langle x_\theta| has Weyl symbol δ(x′cos⁡θ+p′sin⁡θ−x)\delta(x'\cos\theta+p'\sin\theta-x), a delta ridge along the rotated axis, so tracing it against ρ^\hat\rho integrates WW over the perpendicular line — the defining operation of the Radon transform. Because the marginals are Radon projections, the state is recovered by the inversion that reconstructs a CT slice: filtered back-projection. The ramp filter ∣ξ∣|\xi| corrects the low-frequency oversampling of back-projected rays, and the angular integral stitches the filtered projections into the plane.

W(x,p)=14π2∫0π ⁣ ⁣∫−∞∞ ⁣ ⁣∫−∞∞pr(x′,θ) ∣ξ∣ eiξ(xcos⁡θ+psin⁡θ−x′) dξ dx′ dθ(3)W(x,p)=\frac{1}{4\pi^2}\int_0^{\pi}\!\!\int_{-\infty}^{\infty}\!\!\int_{-\infty}^{\infty} \mathrm{pr}(x',\theta)\,|\xi|\,e^{i\xi(x\cos\theta + p\sin\theta - x')}\,\mathrm{d}\xi\,\mathrm{d}x'\,\mathrm{d}\theta \qquad (3)

where: ξ\xi — Fourier variable conjugate to x′x', with ∣ξ∣|\xi| the ramp filter; θ∈[0,π)\theta\in[0,\pi) — the projection angles. Equation (3) is exact for noiseless, complete data, but the ramp filter amplifies high-frequency statistical noise — why raw inversion is treacherous on finite samples and why the field moved to constrained estimators. Often one wants the density matrix in the Fock basis directly. Pattern-function tomography does this in one linear pass over the same histograms: each element ρmn\rho_{mn} is a weighted integral of the data against a precomputed kernel, sidestepping any image.

ρmn=∫0π ⁣ ⁣∫−∞∞pr(x,θ) fmn(x,θ) dx dθπ(4)\rho_{mn}=\int_0^{\pi}\!\!\int_{-\infty}^{\infty} \mathrm{pr}(x,\theta)\, f_{mn}(x,\theta)\,\mathrm{d}x\,\frac{\mathrm{d}\theta}{\pi} \qquad (4)

where: ρmn=⟨m∣ρ^∣n⟩\rho_{mn}=\langle m|\hat\rho|n\rangle — density-matrix element in the number basis; fmn(x,θ)=ei(m−n)θ gmn(x)f_{mn}(x,\theta)=e^{i(m-n)\theta}\,g_{mn}(x) — pattern functions built from the regular and irregular oscillator eigenfunctions. The factor ei(m−n)θe^{i(m-n)\theta} shows the coherence ρmn\rho_{mn} is read off the (m−n)(m-n)-th Fourier component of the data's phase dependence. No detector is perfect, and loss is the dominant systematic. Modelling the overall efficiency η\eta as a beam splitter admixing vacuum, the state actually sampled is the true Wigner function blurred by a Gaussian that widens as η\eta drops — loss only smooths toward classicality, never sharpens.

Wη(x,p)=∫Gη(x−x′,p−p′) W(x′,p′) dx′ dp′,Gη=1πσ2 e−(x2+p2)/σ2,σ2=1−ηη(5)W_\eta(x,p)=\int G_\eta(x-x',p-p')\,W(x',p')\,\mathrm{d}x'\,\mathrm{d}p',\qquad G_\eta=\frac{1}{\pi\sigma^2}\,e^{-(x^2+p^2)/\sigma^2},\quad \sigma^2=\frac{1-\eta}{\eta} \qquad (5)

where: η\eta — overall efficiency (photodiode quantum efficiency ×\times mode overlap ×\times transmission); WηW_\eta — Wigner function sampled by the lossy detector; σ2\sigma^2 — total added variance, (1−η)/(2η)(1-\eta)/(2\eta) per quadrature. When this reaches a full vacuum unit 12\tfrac12 — at η=12\eta=\tfrac12 — the convolution erases all negativity, leaving a Husimi-QQ-like non-negative blob. Homodyne is not the only route. When the mode lives in a microwave cavity, one samples WW point by point with no inversion, using that W(α)W(\alpha) is the expectation of photon-number parity after displacing the state by −α-\alpha.

W(α)=2π Tr ⁣[D^(α) ρ^ D^†(α) Π^]=2π∑n=0∞(−1)n ⟨n∣D^†(α)ρ^D^(α)∣n⟩(6)W(\alpha)=\frac{2}{\pi}\,\mathrm{Tr}\!\left[\hat D(\alpha)\,\hat\rho\,\hat D^\dagger(\alpha)\,\hat\Pi\right]=\frac{2}{\pi}\sum_{n=0}^{\infty}(-1)^n\,\langle n|\hat D^\dagger(\alpha)\hat\rho\hat D(\alpha)|n\rangle \qquad (6)

where: D^(α)=eαa^†−α∗a^\hat D(\alpha)=e^{\alpha\hat a^\dagger-\alpha^*\hat a} — displacement operator; Π^=(−1)n^\hat\Pi=(-1)^{\hat n} — parity operator; α\alpha — phase-space point being read. Royer's identity makes W(α)W(\alpha) the parity expectation in the displaced frame, so displacing the field and measuring P(n)P(n) yields W(α)=2π∑n(−1)nP(n)W(\alpha)=\tfrac{2}{\pi}\sum_n(-1)^nP(n) — the basis of circuit-QED cat-state imaging. Finally, since neither raw inversion nor a linear pattern-function sum guarantees a physical state, serious reconstruction is constrained statistical estimation. The maximum-likelihood estimate is the physical density matrix under which the data are most probable, reached by a fixed-point map that never leaves the physical set.

ρ^ML=arg⁡max⁡ρ^≥0, Trρ^=1 ∑jln⁡ pr(xj,θj ∣ ρ^)(7)\hat\rho_{\mathrm{ML}}=\arg\max_{\hat\rho\ge0,\ \mathrm{Tr}\hat\rho=1}\ \sum_{j}\ln\,\mathrm{pr}(x_j,\theta_j\,|\,\hat\rho) \qquad (7)

where: (xj,θj)(x_j,\theta_j) — the jj-th quadrature value and its phase; ρ^ML\hat\rho_{\mathrm{ML}} — the physical density matrix most likely to have produced the dataset. It is found by the iteration ρ^(k+1)=N[R^ρ^(k)R^]\hat\rho^{(k+1)}=\mathcal N[\hat R\hat\rho^{(k)}\hat R] with R^=∑jΠ^j/pr(xj,θj∣ρ^(k))\hat R=\sum_j\hat\Pi_j/\mathrm{pr}(x_j,\theta_j|\hat\rho^{(k)}); N\mathcal N restores unit trace each step, and the POVM elements Π^j\hat\Pi_j can absorb the efficiency model so the estimate is loss-corrected.

Derivation AWhy the homodyne difference current reads the rotated quadrature

The goal is to show from the beam-splitter algebra that balanced homodyne detection, fed by a bright coherent local oscillator, produces a photocurrent difference proportional to the signal quadrature x^θ\hat x_\theta, and to see why both the balanced subtraction and the strong-oscillator limit are essential — the first cancels the oscillator's classical intensity noise, the second amplifies a single-photon-scale quadrature above electronic noise. We combine signal and oscillator on a 50:50 splitter, form the photon-number difference, and take the classical limit for the oscillator.

Step 1. A balanced beam splitter maps the inputs to c^=12(a^s+a^L)\hat c=\tfrac{1}{\sqrt2}(\hat a_s+\hat a_L) and d^=12(a^s−a^L)\hat d=\tfrac{1}{\sqrt2}(\hat a_s-\hat a_L), with a^s\hat a_s the signal and a^L\hat a_L the oscillator. Why: interfering the weak signal with a strong reference puts the signal information into an interference term, not the tiny signal intensity.

Step 2. The output photon-number difference is n^−=c^†c^−d^†d^=a^s†a^L+a^L†a^s\hat n_-=\hat c^\dagger\hat c-\hat d^\dagger\hat d=\hat a_s^\dagger\hat a_L+\hat a_L^\dagger\hat a_s; the self-energy terms a^s†a^s\hat a_s^\dagger\hat a_s and a^L†a^L\hat a_L^\dagger\hat a_L have equal sign in both outputs and cancel. Why: this cancellation is the point of balanced detection — the oscillator's large, noisy intensity drops out, leaving only the signal-oscillator beat.

Step 3. In the strong-oscillator limit a^L→αL=∣αL∣eiθ\hat a_L\to\alpha_L=|\alpha_L|e^{i\theta} (its fluctuations negligible beside ∣αL∣|\alpha_L|), giving n^−=∣αL∣(a^se−iθ+a^s†eiθ)=2 ∣αL∣ x^θ\hat n_-=|\alpha_L|\big(\hat a_s e^{-i\theta}+\hat a_s^\dagger e^{i\theta}\big)=\sqrt2\,|\alpha_L|\,\hat x_\theta. Why: the oscillator phase θ\theta is imprinted as the projection angle, and ∣αL∣|\alpha_L| is a built-in gain lifting a single-photon quadrature above the electronic noise floor.

Step 4. Sweeping θ\theta selects which quadrature is measured; repeating at fixed θ\theta over many copies fills the histogram pr(x,θ)\mathrm{pr}(x,\theta) after dividing out 2 ∣αL∣\sqrt2\,|\alpha_L|. Why: this is exactly the family of projections equation (2) needs, so a phase-swept balanced homodyne detector is a complete Radon-projection camera — the standard result of Loudon and of Saleh and Teich.

Go deeper · Derivation B · 1 minThe vacuum tomogram and the shot-noise calibration
Derivation BThe vacuum tomogram and the shot-noise calibration

The goal is to establish the reference against which every reconstructed variance is measured: the vacuum quadrature distribution. We compute the second moment of x^θ\hat x_\theta in the vacuum, show it equals 12\tfrac12 for all θ\theta, and identify the resulting Gaussian as the shot-noise floor — the round zero-point noise disk, below which a squeezed state dips at one phase and above which it rises at the conjugate. Without this calibration a homodyne trace is just volts; with it, every number acquires physical meaning.

Step 1. Write the rotated quadrature in ladder operators, x^θ=12(a^ e−iθ+a^†eiθ)\hat x_\theta=\tfrac{1}{\sqrt2}(\hat a\,e^{-i\theta}+\hat a^\dagger e^{i\theta}). Why: in a^,a^†\hat a,\hat a^\dagger the vacuum property a^∣0⟩=0\hat a|0\rangle=0 does all the work and the θ\theta-independence is manifest.

Step 2. The first moment vanishes, and in the second only the survivor contributes: ⟨0∣x^θ2∣0⟩=12⟨0∣a^a^†∣0⟩=12⟨0∣(a^†a^+1)∣0⟩=12\langle0|\hat x_\theta^2|0\rangle=\tfrac12\langle0|\hat a\hat a^\dagger|0\rangle=\tfrac12\langle0|(\hat a^\dagger\hat a+1)|0\rangle=\tfrac12. Why: the phase-carrying cross terms a^2e−2iθ\hat a^2e^{-2i\theta}, a^†2e2iθ\hat a^{\dagger2}e^{2i\theta} have zero vacuum expectation, so the variance is exactly 12\tfrac12 for every θ\theta — the vacuum noise is isotropic.

Step 3. The distribution is Gaussian, prvac(x,θ)=∣⟨xθ∣0⟩∣2=π−1/2e−x2\mathrm{pr}_{\mathrm{vac}}(x,\theta)=|\langle x_\theta|0\rangle|^2=\pi^{-1/2}e^{-x^2}, a round disk of variance 12\tfrac12. Why: it is the projection of the vacuum's symmetric Wigner mound W0=π−1e−(x2+p2)W_0=\pi^{-1}e^{-(x^2+p^2)} and fixes the shot-noise reference — any reconstructed variance below 12\tfrac12 is squeezing, and a squeezed–anti-squeezed pair obeys ⟨Δx2⟩⟨Δp2⟩≥14\langle\Delta x^2\rangle\langle\Delta p^2\rangle\ge\tfrac14. The value 12\tfrac12 follows from [x^,p^]=i[\hat x,\hat p]=i, as in Loudon and Foot.

Go deeper · Derivation C · 1 minLoss as vacuum admixture and the negativity threshold η greater than one half
Derivation CLoss as vacuum admixture and the negativity threshold η greater than one half

The goal is to derive the most consequential constraint in optical tomography: Wigner negativity is observable only when the overall efficiency exceeds one half. We model an imperfect detector as a perfect one preceded by a beam splitter that leaks vacuum in, follow the effect through the characteristic function where the admixture is a Gaussian multiplication, and translate back to phase space where it becomes a convolution that washes out every negative feature.

Step 1. Represent efficiency η\eta by a^→η a^+1−η v^\hat a\to\sqrt{\eta}\,\hat a+\sqrt{1-\eta}\,\hat v, with v^\hat v a vacuum mode entering the empty port of a transmissivity-η\eta splitter; trace out v^\hat v. Why: this is the universal model of linear loss — finite quantum efficiency, imperfect mode matching, and transmission all collapse into one η\eta and one admixed vacuum.

Step 2. In the symmetric-ordered characteristic function the map is χη(λ)=χ(η λ) e−12(1−η)∣λ∣2\chi_\eta(\lambda)=\chi(\sqrt\eta\,\lambda)\,e^{-\frac12(1-\eta)|\lambda|^2}: the argument rescales by η\sqrt\eta and the vacuum adds a Gaussian factor. Why: characteristic functions turn the admixture into a product, easier to track than the phase-space integral, and the Gaussian factor is the imprint of leaked-in zero-point noise.

Step 3. Transforming back, the product becomes a convolution Wη=Wrescaled∗GηW_\eta=W_{\text{rescaled}}\ast G_\eta, with GηG_\eta of intrinsic variance (1−η)/2(1-\eta)/2, equivalently (1−η)/(2η)(1-\eta)/(2\eta) per quadrature at the input. Why: a Gaussian product in one domain is a smoothing convolution in the conjugate one, so loss can only blur WW toward Gaussian positivity, never sharpen it.

Step 4. Once the added per-quadrature variance reaches a full vacuum unit 12\tfrac12 — i.e. (1−η)/(2η)≥12(1-\eta)/(2\eta)\ge\tfrac12, or η≤12\eta\le\tfrac12 — the convolution renders any Wigner function non-negative, the Husimi-QQ limit. Why: the headline constraint. For η≤12\eta\le\tfrac12 no sampled tomogram can show negativity, so certifying it demands η>12\eta>\tfrac12 — an established result of Lvovsky and Raymer, Rev. Mod. Phys. 81, 299 (2009).

Limiting cases

Whether a reconstruction is trustworthy, and whether it can reveal nonclassicality at all, is governed by three knobs: the detection efficiency η\eta, the number of copies NN, and the phase-space extent of the state relative to the Hilbert-space cutoff.

CaseResultMeaning
Unit efficiency, infinite dataη→1, N→∞\eta\to1,\ N\to\inftyThe inverse Radon transform is exact and unbiased; W(x,p)W(x,p) and every ρmn\rho_{mn} are recovered without artifact. The idealized textbook limit that finite experiments only approach.
Loss threshold for negativityη>12\eta>\tfrac12For η≤12\eta\le\tfrac12 the loss-convolved Wigner function of any state is provably non-negative, so negativity cannot be observed directly and can only be inferred by deconvolution under extra assumptions.
Gaussian stateW(r)=12πdet⁡Σ e−12rTΣ−1rW(\mathbf r)=\dfrac{1}{2\pi\sqrt{\det\Sigma}}\,e^{-\frac12\mathbf r^{\mathsf T}\Sigma^{-1}\mathbf r}Fully fixed by the 2×22\times2 covariance matrix Σ\Sigma and the mean; a handful of quadrature variances suffice, and full tomography merely confirms Gaussianity.
Finite Hilbert-space truncationρmn=0\rho_{mn}=0 for m,n>Nmax⁡m,n>N_{\max}Maximum-likelihood tomography needs a photon-number cutoff above the state's support: too small biases the estimate, too large overfits statistical noise.

Worked examples

1 · How deep is the single-photon dip, and how much loss can it survive? (confidence builder)

A heralded single photon has Wigner function W(x,p)=1π(2(x2+p2)−1)e−(x2+p2)W(x,p)=\tfrac1\pi\big(2(x^2+p^2)-1\big)e^{-(x^2+p^2)}. Find its value at the phase-space origin, then find the measured central value after passing through a detector of efficiency η\eta, and determine the efficiency below which the negativity is no longer observable.

Step 1. Evaluate at the origin: x=p=0x=p=0 gives W(0,0)=1π(0−1)=−1πW(0,0)=\tfrac1\pi(0-1)=-\tfrac1\pi. Numerically W(0,0)=−1/π=−0.318W(0,0)=-1/\pi=\mathbf{-0.318}, a deep hole at the center of phase space — the classically forbidden signature the whole measurement exists to see.

Step 2. Model loss. A single photon through a transmissivity-η\eta splitter becomes ρ^η=(1−η) ∣0⟩⟨0∣+η ∣1⟩⟨1∣\hat\rho_\eta=(1-\eta)\,|0\rangle\langle0|+\eta\,|1\rangle\langle1|: lost with probability 1−η1-\eta (to vacuum), surviving with probability η\eta. Since WW is linear in ρ^\hat\rho, and W∣0⟩(0,0)=+1πW_{|0\rangle}(0,0)=+\tfrac1\pi, W∣1⟩(0,0)=−1πW_{|1\rangle}(0,0)=-\tfrac1\pi.

Step 3. Combine: Wη(0,0)=(1−η)1π−η1π=1−2ηπW_\eta(0,0)=(1-\eta)\tfrac1\pi-\eta\tfrac1\pi=\dfrac{1-2\eta}{\pi}. At η=0.6\eta=0.6, (1−1.2)/π=−0.064(1-1.2)/\pi=\mathbf{-0.064} — still negative, still certifiable. At η=0.45\eta=0.45, (1−0.9)/π=+0.032(1-0.9)/\pi=+\mathbf{0.032} — positive, the hole filled in. The sign flips exactly at η=12\eta=\tfrac12.

Step 4. Conclusion: negativity is observable only for η>1/2\mathbf{\eta>1/2}, in exact agreement with the general loss-convolution threshold. The pure dip is −1/π≈−0.318-1/\pi\approx-0.318; at η=0.6\eta=0.6 it reads −0.064-0.064; below η=1/2\eta=1/2 it vanishes.

2 · Reading a squeezed-vacuum tomogram in decibels

A homodyne tomogram of squeezed vacuum returns a minimum quadrature variance Vmin⁡=0.125V_{\min}=0.125 (shot noise is 12\tfrac12). Express the squeezing in decibels, find the minimum possible anti-squeezed variance for a pure state, and say what a measured Vmax⁡=3.0V_{\max}=3.0 would imply.

Step 1. Squeezing in dB compares the variance to the vacuum floor: S=10log⁡10(Vvac/Vmin⁡)=10log⁡10(0.5/0.125)=10log⁡104=6.02 dBS=10\log_{10}(V_{\text{vac}}/V_{\min})=10\log_{10}(0.5/0.125)=10\log_{10}4=\mathbf{6.02\ dB} of noise reduction below shot noise at the squeezed phase.

Step 2. The uncertainty product Vmin⁡Vmax⁡≥14V_{\min}V_{\max}\ge\tfrac14 (from [x^,p^]=i[\hat x,\hat p]=i) forces Vmax⁡≥0.25/0.125=2.0V_{\max}\ge0.25/0.125=\mathbf{2.0} for a minimum-uncertainty (pure) state, i.e. exactly 10log⁡10(2.0/0.5)=6.0210\log_{10}(2.0/0.5)=6.02 dB of anti-squeezing — a symmetric 6.026.02 dB up and down.

Step 3. A measured Vmax⁡=3.0V_{\max}=3.0 gives Vmin⁡Vmax⁡=0.125×3.0=0.375>14V_{\min}V_{\max}=0.125\times3.0=0.375>\tfrac14, so the state is not minimum uncertainty — the excess 0.375−0.25=0.1250.375-0.25=0.125 is added technical or thermal noise, and the tomogram is flagging an impure source. (For scale, a realistic budget of photodiode 0.99×0.99\times visibility2 (0.98)2×^2\,(0.98)^2\times transmission 0.950.95 gives η≈0.90>12\eta\approx0.90>\tfrac12, so negativity stays certifiable.) 6.02 dB squeezed; a pure state needs Vmax⁡=2.0V_{\max}=2.0; Vmax⁡=3.0V_{\max}=3.0 signals excess noise.

Physics of the portrait

Optical homodyne tomography is where a piece of medical-imaging mathematics, a quantum-optics detector, and a decades-old question about measuring a quantum state converge into a single working camera for light.

Origins · 1 minoptical homodyne tomography and how this was discovered
OH
optical homodyne tomography
reconstructing the Wigner function from its quadrature shadows · quantum optical measurement

The idea that a quantum state could be measured at all — not just predicted — is older than the optics that realized it. Eugene Wigner introduced his phase-space quasiprobability distribution in 1932 as a calculational device, never imagining it photographed; Ugo Fano in 1957 framed the problem sharply, arguing that determining an unknown state requires a "quorum" of observables sufficient to fix every element of ρ^\hat\rho. For decades this stayed abstract, since no one had a practical quorum for a light field. The unlock came sideways: Kurt Vogel and Hans Risken realized in 1989 that the quadrature distributions a homodyne detector already produced were the Radon projections of the Wigner function — the very data an X-ray CT scanner inverts — so the whole apparatus of tomographic reconstruction could be imported wholesale. Michael Raymer's group turned the insight into an instrument, reconstructing the Wigner function of squeezed vacuum in 1993 and giving birth to optical homodyne tomography. The raw inversion's statistical pathologies drove a second revolution, as Zdeněk Hradil recast reconstruction as maximum-likelihood estimation in 1997 and Alexander Lvovsky and collaborators used it in 2001 to image, for the first time, the negative Wigner dip of a single photon. What Fano posed as a question of principle had become, within a lifetime, a benchmark run daily on quantum-optics tables.

History
1932
— Wigner introduces the phase-space quasiprobability distribution
1957
— Fano frames state determination as measuring a sufficient quorum of observables
1989
— Vogel and Risken identify the homodyne quadrature marginals as Radon projections of the Wigner function
1993
— Smithey, Beck, Raymer and Faridani reconstruct the Wigner function of squeezed vacuum
1997
— Hradil recasts state reconstruction as maximum-likelihood estimation
2001
— Lvovsky and colleagues image the Wigner negativity of a single photon

Going further

Texts. Loudon, The Quantum Theory of Light, 3rd ed., Ch. 6 (homodyne detection and quadratures) · Leonhardt, Measuring the Quantum State of Light (the dedicated monograph on optical tomography) · Saleh and Teich, Fundamentals of Photonics, 3rd ed. (quantum optics chapters) · Foot, Atomic Physics, Ch. 7 (coherent states and field measurement) · Demtröder, Laser Spectroscopy, Vol. 1 (homodyne and heterodyne detection). Papers. Vogel and Risken, Phys. Rev. A 40, 2847 (1989) · Smithey, Beck, Raymer and Faridani, Phys. Rev. Lett. 70, 1244 (1993) · Lvovsky and Raymer, Rev. Mod. Phys. 81, 299 (2009).

Provenance. All physics uses the ℏ→1\hbar\to1, [x^,p^]=i[\hat x,\hat p]=i convention (vacuum quadrature variance 12\tfrac12); rescale for [x^,p^]=i/2[\hat x,\hat p]=i/2. A verifier should recompute: (1) n^−=2 ∣αL∣ x^θ\hat n_-=\sqrt2\,|\alpha_L|\,\hat x_\theta (Loudon Ch. 6; Saleh and Teich); (2) ⟨Δx^θ2⟩=12\langle\Delta\hat x_\theta^2\rangle=\tfrac12 from [x^,p^]=i[\hat x,\hat p]=i; (3) the marginal/Radon identity pr(x,θ)=∫W dpθ\mathrm{pr}(x,\theta)=\int W\,\mathrm{d}p_\theta and its inverse (Vogel and Risken 1989); (4) W(x,p)=π−1(2(x2+p2)−1)e−(x2+p2)W(x,p)=\pi^{-1}(2(x^2+p^2)-1)e^{-(x^2+p^2)} with W(0,0)=−1/π≈−0.318W(0,0)=-1/\pi\approx-0.318, normalization to unity, and lossy value Wη(0,0)=(1−2η)/πW_\eta(0,0)=(1-2\eta)/\pi; (5) the loss convolution and the η>12\eta>\tfrac12 threshold (Lvovsky and Raymer, RMP 81, 299, 2009); (6) Royer's displaced-parity formula. No non-standard numerical values are asserted.

Prerequisites. Quadrature Operators and the Uncertainty Relation · Phase-Space Quasiprobability Distributions · Coherent States · Fock States and the Photon-Number Basis. Leads to. Squeezed States of Light · Single-Photon Sources · Photon Statistics and the Mandel Q Parameter.

Ask the tutor: Ask me to walk through reconstructing a specific state — squeezed vacuum, a heralded single photon, or a cat — from its quadrature histograms, and we will trace every projection into the final Wigner image.

Doesn't measuring the state violate the uncertainty principle, since it needs both x̂ and p̂?

No — tomography never co-measures conjugate quadratures on one copy. Each pulse is destroyed by a single homodyne measurement of one quadrature x^θ\hat x_\theta at one phase θ\theta, fully respecting complementarity. What is reconstructed is a statistical distribution over an ensemble of identical copies, not a joint value for one copy. The uncertainty relation constrains the reconstructed state — a variance below 12\tfrac12 in one quadrature forces one above 12\tfrac12 in the conjugate, product at least 14\tfrac14 — but never blocks the reconstruction. Tomography buys complete information by spending many copies, one quadrature each.

Why sweep θ only over 0 to π, and not the full 0 to 2π?

Because x^θ+π=−x^θ\hat x_{\theta+\pi}=-\hat x_\theta: rotating the phase by π\pi measures the same axis, merely relabeling the outcome xx as −x-x. The projection at θ+π\theta+\pi carries no new information — it is the same shadow seen from the opposite side. A half-circle already contains every distinct direction through phase space, exactly as in CT imaging, where 00 to π\pi suffices to reconstruct a slice. Sweeping the full 2π2\pi just doubles the data on each axis, though the redundancy can help average down noise in practice.

Does tomography give me the Wigner function or the density matrix — and are they the same thing?

They are equivalent representations of one object, and tomography can target either. W(x,p)W(x,p) and ρ^\hat\rho are related by an invertible transform, so knowing one is knowing the other; WW is the phase-space picture, ρ^\hat\rho the operator. Filtered back-projection (equation 3) yields WW, while pattern-function tomography (equation 4) and maximum-likelihood estimation (equation 7) yield ρ^\hat\rho directly in the Fock basis. One chooses by the state: Gaussian-ish continuous-variable states are intuitive as Wigner images, while few-photon states are cleaner as small density matrices with an explicit cutoff.

How many copies do I actually need for a good reconstruction?

There is no single number — it scales with the state's complexity and the precision demanded. A Gaussian state is pinned by a handful of moments, so a few thousand samples over a dozen phases give a tight covariance matrix. Resolving the negativity of a single photon or the fringes of a cat needs far more: typically 10510^5 to 10610^6 quadrature values across many phases, since you estimate many density-matrix elements and each error falls only as 1/N1/\sqrt N. Maximum-likelihood uses the data more efficiently than back-projection, but the scaling with the truncated Hilbert-space size still sets the budget.

Why is Wigner negativity treated as the gold standard for "genuinely quantum"?

Because no classical model of light can reproduce it. A negative region of WW means the state is not a probabilistic mixture of coherent states — no classical field ensemble, however noisy, gives those statistics. Since loss only ever blurs WW toward positivity, an observed negative dip, honestly efficiency-corrected, is an assumption-light certificate of nonclassicality, and hence the benchmark for single-photon and cat sources. The caveat is the loss threshold: for η≤12\eta\le\tfrac12 the sampled tomogram is provably non-negative, so any negativity claimed there rests on a deconvolution model and must be scrutinized.

Can the state be measured without homodyning, for example in the microwave regime?

Yes, and it must be, since bright optical-style local oscillators and fast photodiodes are impractical for single microwave photons. The workhorse is displaced-parity tomography (equation 6): a superconducting qubit or Rydberg atom displaces the cavity field by a chosen α\alpha, then reads the photon-number parity (−1)n^(-1)^{\hat n} through the qubit's Ramsey phase. Royer's identity makes that parity expectation, up to 2/π2/\pi, the Wigner value W(α)W(\alpha) itself — so scanning α\alpha maps WW point by point with no Radon inversion. This is how circuit-QED experiments image cat states and diagnose bosonic error-correction codes.

Before this

Where this leads