The Heart & Cardiac Cycle
Every beat of your heart moves roughly 70 mL of blood in about 0.8 seconds. It does so with such reliable mechanical logic that a trained clinician can diagnose a leaking valve just by listening. How does a fist-sized muscular pump generate the pressures needed to push blood through 100,000 km of vessels? How does it ensure blood flows in only one direction? How does it do this roughly 100,000 times a day, without valves that stick or chambers that overfill? The answer lies in a precisely choreographed sequence of pressure and volume changes called the cardiac cycle. The cardiac cycle matters because nearly all of cardiovascular physiology depends on it. Blood pressure, cardiac output, heart sounds, murmurs, and the effects of drugs and disease on circulation all rely on it. This is built on understanding what the heart's four chambers and four valves are doing at each instant of a heartbeat. Heart failure, valve stenosis, arrhythmia, and shock all disrupt this cycle in predictable, mechanistically explainable ways. This is why the pressure-volume relationships described here form the backbone of cardiology. The big picture is elegantly mechanical. The heart is two synchronized pumps in series: right heart to lungs, left heart to body. Each pump consists of a low-pressure receiving chamber (atrium) and a high-pressure ejecting chamber (ventricle). These chambers are separated and protected by one-way valves. These valves open and close purely in response to pressure gradients — no muscles operate them directly. Contraction (systole) and relaxation (diastole) alternate rhythmically. By tracking left ventricular pressure and volume through one cycle, you can derive stroke volume, ejection fraction, and the origin of every normal heart sound. This article builds the chamber and valve anatomy. It walks step by step through the pressure-volume events of one heartbeat. It presents the classic physiological evidence — pressure-catheter recordings and the Wiggers diagram — that established this model. It works two quantitative examples: a normal stroke volume/ejection fraction calculation and a valve-stenosis case. It then addresses common misconceptions and clinical relevance.
- The heart is two pumps in series: right heart (pulmonary circuit) and left heart (systemic circuit), each with an atrium and ventricle.
- Valves are passive, pressure-driven flaps: AV valves (tricuspid, mitral) separate atria from ventricles; semilunar valves (pulmonary, aortic) separate ventricles from arteries.
- One cardiac cycle = diastole (filling) + systole (ejection), lasting ~0.8 s at 75 bpm, split roughly two-thirds diastole and one-third systole.
- Two heart sounds mark valve closure: S1 (AV valves close, start of systole) and S2 (semilunar valves close, start of diastole).
- Stroke volume = end-diastolic volume − end-systolic volume; ejection fraction (normally ~55–70%) is stroke volume divided by end-diastolic volume.
- The Wiggers diagram — simultaneous pressure, volume, ECG, and heart sound tracings — is the classic experimental synthesis proving this whole sequence.
Blood always moves down a pressure gradient, and every valve opening or closing in the heart is simply a passive consequence of which chamber currently has higher pressure.
The core idea
The heart is best understood not as one pump but as two pumps arranged in series, sharing a common wall (the septum) and beating in synchrony. The right heart (right atrium + right ventricle) receives deoxygenated blood from the body and pumps it through the pulmonary circuit to the lungs at low pressure. The left heart (left atrium + left ventricle) receives oxygenated blood from the lungs and pumps it through the systemic circuit to the entire body at much higher pressure. Because the two ventricles are in series, in the steady state they must eject the same stroke volume per beat — otherwise blood would pool in one circuit. Each side has two valves. Atrioventricular (AV) valves — the tricuspid valve on the right, the mitral (bicuspid) valve on the left — sit between atrium and ventricle and prevent backflow into the atria during ventricular contraction. Semilunar valves — the pulmonary valve on the right, the aortic valve on the left — sit between ventricle and great artery and prevent backflow into the ventricles during relaxation. Crucially, none of these valves has its own muscle to open or shut it deliberately; each is a flap of tissue that opens when pressure upstream exceeds pressure downstream and slams shut when the gradient reverses. This single fact — valves are passive, pressure-gated check valves — explains essentially every heart sound, murmur, and pressure waveform you will ever interpret. The cardiac cycle is the repeating sequence of mechanical events — chamber pressure changes, volume changes, and valve opening/closing — that occurs during one heartbeat, divided into diastole (the ventricles relax and fill) and systole (the ventricles contract and eject). Understanding the cycle means tracking, moment to moment, which chamber has the highest pressure and therefore which valves are open, closed, or in the act of slamming shut. This framework connects directly to Cardiac Action Potential & Conduction (the electrical trigger for each contraction), Cardiac Output & Its Regulation (how stroke volume and heart rate combine to set flow), and Blood Pressure & Its Regulation (how ejected volume and arterial properties set systemic pressure).
Mechanism
Chamber and valve anatomy. Blood flows: systemic veins → right atrium → tricuspid valve → right ventricle → pulmonary valve → pulmonary artery → lungs → pulmonary veins → left atrium → mitral valve → left ventricle → aortic valve → aorta → systemic circulation. The left ventricle wall is roughly 2–3 times thicker than the right ventricle wall because it must generate systemic arterial pressures (~120/80 mmHg) versus pulmonary pressures (~25/8 mmHg) — a direct structure-function match to the resistance each pump faces. The AV valves are tethered by chordae tendineae to papillary muscles, which contract with the ventricular wall to prevent the valve leaflets from prolapsing backward into the atria under high ventricular pressure.
The seven phases of one cardiac cycle, tracked through the left heart (the right heart does the same thing at lower pressures, simultaneously): 1. Atrial systole. The atrium contracts, topping off the ventricle with the final ~20–30% of end-diastolic volume ("atrial kick"). Atrial pressure briefly exceeds ventricular pressure. AV valve open, semilunar valve closed. 2. Isovolumetric contraction. Ventricular systole begins (triggered by the QRS complex of the ECG). Ventricular pressure rises steeply. As soon as it exceeds atrial pressure, the AV valve snaps shut — producing heart sound S1. Because both valves are now closed, ventricular volume cannot change even though pressure is rising rapidly — hence "isovolumetric." 3. Ventricular ejection (rapid, then reduced). Once ventricular pressure exceeds aortic pressure (~80 mmHg), the aortic valve opens and blood is ejected. Ejection is fastest early (rapid ejection) then slows (reduced ejection) as ventricular pressure peaks (~120 mmHg) and begins to fall. 4. Isovolumetric relaxation. The ventricle begins diastole; pressure falls quickly. When ventricular pressure drops below aortic pressure, the aortic valve snaps shut — producing heart sound S2. Both valves closed again; volume constant while pressure plummets. 5. Rapid ventricular filling. Once ventricular pressure falls below atrial pressure, the AV valve opens and blood that has been accumulating in the atrium rushes into the ventricle. 6. Diastasis. Filling slows to a trickle as atrial and ventricular pressures nearly equalize; this is the longest but least dramatic phase, shortened markedly at high heart rates. 7. Return to atrial systole, closing the loop.
Key volumes. End-diastolic volume (EDV, ~120–130 mL) is the volume just before contraction begins; end-systolic volume (ESV, ~50–60 mL) is what remains after ejection. Stroke volume (SV = EDV − ESV) is therefore ~70 mL, and ejection fraction (EF = SV/EDV) is normally 55–70%. Note the ventricle never empties completely — a physiological reserve that matters enormously when contractility falls in heart failure.
Heart sounds and their mechanistic origin. S1 ("lub") is caused by the abrupt closure of the AV valves and the vibration of blood and ventricular walls when this happens, marking the start of isovolumetric contraction. S2 ("dub") is caused by the closure of the semilunar valves at the start of isovolumetric relaxation. A third sound (S3), sometimes normal in children and young adults but pathological in older adults, corresponds to turbulent rapid filling; a fourth sound (S4) corresponds to atrial contraction against a stiff ventricle. Murmurs are turbulence noises caused by valves that don't open fully (stenosis) or don't close fully (regurgitation/insufficiency) — their timing within the cycle (systolic vs. diastolic) pinpoints which valve is diseased.
The evidence
The modern picture of the cardiac cycle was assembled from two complementary lines of evidence separated by decades: direct pressure measurement inside living hearts, and the graphical synthesis that turned those measurements into a teachable model.
Carl Wiggers and simultaneous multi-channel recording (1910s–1920s). Working at Western Reserve University, physiologist Carl J. Wiggers built instrumentation to record, simultaneously and in real time, aortic pressure, left ventricular pressure, left atrial pressure, ventricular volume, the ECG, and phonocardiogram (heart sound) tracings from experimental animals (primarily dogs), using pressure transducers connected via fluid-filled catheters and optical recording systems. Before this, physiologists had measured these variables in isolation, making it hard to establish exact temporal relationships — for instance, precisely when in the pressure cycle a valve closure sound occurred. Wiggers' innovation was temporal alignment: by recording all signals on the same moving photographic paper against a common time base, he could show, for the first time with rigor, that the first heart sound coincides exactly with the crossover of atrial and ventricular pressure (AV valve closure) and the second heart sound coincides with the crossover of ventricular and aortic pressure (semilunar valve closure). This composite chart — pressure curves for aorta, ventricle, and atrium, plotted against ventricular volume, the ECG, and phonocardiogram, all on one time axis — is now called the Wiggers diagram and remains the canonical figure used to teach the cardiac cycle in every physiology course.
Direct cardiac catheterization confirms the model in humans. Wiggers' data came from animal models with externally implanted transducers, leaving open the question of whether human hearts behaved identically. This was settled by Werner Forssmann, who in 1929 performed cardiac catheterization on himself — threading a urinary catheter through his own antecubital vein into his right atrium and confirming its position by X-ray — demonstrating that direct access to human heart chambers was possible without lethal consequence, a claim his supervisors had considered too dangerous to test. This opened the door for André Cournand and Dickinson Richards in the 1940s to refine catheterization into a quantitative diagnostic tool, directly measuring right heart and pulmonary artery pressures in human patients and validating that the pressure sequences Wiggers described in dogs held true in humans. Forssmann, Cournand, and Richards jointly received the Nobel Prize in Physiology or Medicine in 1956 for this work. Later refinements — most notably the balloon-tipped, flow-directed Swan-Ganz catheter developed by Jeremy Swan and William Ganz in 1970 — allowed pulmonary capillary wedge pressure (a proxy for left atrial pressure) to be measured at the bedside, extending Wiggers-diagram physiology directly into clinical cardiology and critical care. Together, these experiments established, with quantitative pressure-tracing evidence rather than inference, that (1) valve opening and closing are governed strictly by the sign of the pressure gradient across them, (2) heart sounds correspond precisely to specific valve closure events, and (3) the same qualitative pressure sequence holds across species including humans, differing mainly in absolute pressures and cycle duration.
Worked examples
Example 1 — Stroke volume and ejection fraction from echocardiographic volumes. A patient's echocardiogram reports an end-diastolic volume of 142 mL and an end-systolic volume of 58 mL. Heart rate is 68 beats/min. Step 1 — stroke volume: SV = EDV − ESV = 142 − 58 = 84 mL Step 2 — ejection fraction: EF = SV / EDV = 84 / 142 = 0.592 ≈ 59% This falls within the normal range (55–70%), so despite an EDV that is somewhat above the textbook average (~120–130 mL, perhaps reflecting a larger body size or elevated preload), the ventricle's pumping efficiency is normal — a useful distinction, since EDV alone doesn't diagnose dysfunction. Step 3 — cardiac output: CO = SV × HR = 84 mL × 68 /min = 5712 mL/min ≈ 5.7 L/min, within the normal resting range of 4–8 L/min, foreshadowing the calculations central to Cardiac Output & Its Regulation. If this patient's EF had instead been 30% (say, EDV 180 mL, ESV 126 mL, SV 54 mL), the diagnosis would shift toward systolic heart failure: the ventricle fills to a larger-than-normal volume (elevated preload, often from fluid retention) yet ejects a smaller fraction of it, because impaired contractility prevents ventricular pressure from rising fast or high enough to eject blood efficiently.
Example 2 — Aortic stenosis and its pressure-volume consequences. A patient has calcific aortic stenosis: the aortic valve leaflets are thickened and the valve orifice is narrowed from a normal ~3–4 cm² to 0.7 cm² (severe stenosis). Reasoning through the cycle: during isovolumetric contraction, left ventricular pressure must rise as usual until it exceeds aortic pressure to force the valve open — but because the orifice is narrow, ejecting the same stroke volume through it requires a much larger pressure gradient (analogous to needing higher pressure to push the same flow through a narrower pipe, following principles related to the Hagen–Poiseuille relationship, where resistance rises sharply as radius decreases). Consequently:
- Peak LV systolic pressure rises dramatically (commonly to 180–200+ mmHg) while aortic pressure downstream stays only modestly elevated or even low-normal — creating a large trans-valvular pressure gradient (often >40 mmHg at peak, versus a normal near-zero gradient across an open valve).
- The ejection phase becomes prolonged and turbulent, generating a harsh systolic murmur (crescendo-decrescendo, heard between S1 and S2, the exact timing predicted by the mechanism above) as blood jets through the narrow orifice.
- Chronic pressure overload causes the LV wall to thicken (concentric hypertrophy) as a compensatory response, increasing contractile force to overcome the fixed outflow obstruction — but this thickened wall also becomes stiffer, impairing diastolic filling and elevating end-diastolic pressure, which can back up into the pulmonary circuit and cause breathlessness.
- Ejection fraction can remain deceptively normal for years, because the hypertrophied muscle compensates — masking the severity of obstruction until the ventricle eventually decompensates.
This example shows how a single anatomical lesion (a narrowed valve orifice) predictably deranges every phase of the pressure-volume cycle discussed above, and why murmur timing is a direct clinical readout of the underlying mechanism.
Common misconceptions & traps
| Misconception | Why it's wrong |
|---|---|
| "Valves are actively opened and shut by muscles." | Valves are passive flaps; opening/closing is driven purely by which side has higher pressure. There is no valve-closing muscle (papillary muscles stabilize AV valve leaflets via chordae tendineae, they don't shut the valve). |
| "The heart empties completely with each beat." | Even at rest, ~40–45% of end-diastolic volume remains as end-systolic volume; EF is normally 55–70%, not 100%. |
| "Atrial contraction is the main filling mechanism." | ~70–80% of ventricular filling happens passively during rapid filling before the atrium even contracts; the atrial kick only adds the final increment, which becomes more important at high heart rates or when ventricular compliance is reduced. |
| "S1 and S2 are caused by blood flow itself, not the valves." | The sounds arise mainly from the abrupt tensing/closure of the valve leaflets and the resulting vibration of adjacent structures, not simply flow noise. |
| "Systole and diastole take equal time." | At resting heart rates, diastole occupies roughly two-thirds of the cycle and systole one-third; as heart rate rises, diastole shortens disproportionately, which is why very high heart rates impair filling. |
The scientist behind it
Origins · 1 minCarl J. Wiggers and how this was discovered
Carl Wiggers was an American cardiovascular physiologist whose defining contribution was methodological: he engineered ways to record multiple physiological signals — arterial pressure, ventricular pressure, atrial pressure, ventricular volume, the electrocardiogram, and phonocardiogram — simultaneously and on a common time base, primarily in anesthetized dog preparations with surgically implanted pressure transducers and optical recording apparatus. Earlier physiologists had characterized these signals individually, but Wiggers' insistence on precise temporal alignment let him demonstrate, rather than merely infer, the exact causal sequence linking pressure crossovers to valve closure and to heart sounds. He directed the Department of Physiology at Western Reserve for over three decades, trained generations of cardiovascular physiologists, and authored influential textbooks that helped standardize how the cardiac cycle is taught. The diagram bearing his name remains, essentially unchanged in structure, the central didactic figure of cardiovascular physiology a century later.
Where this matters today
Understanding the cardiac cycle underlies nearly all of modern cardiology and much of critical care medicine. Echocardiography measures EDV, ESV, ejection fraction, and valve gradients non-invasively, using exactly the pressure-volume logic described above to diagnose heart failure, valve stenosis, and regurgitation. Cardiac catheterization and coronary angiography, direct descendants of Forssmann's self-experiment, remain routine procedures for measuring intracardiac pressures and diagnosing valvular and coronary disease. Prosthetic and bioprosthetic heart valves, implanted in patients with severe stenosis or regurgitation, are engineered specifically to replicate passive, pressure-gated opening and closing behavior with minimal turbulence and no mechanical actuator. Auscultation — listening for S1, S2, murmurs, and gallops — remains a frontline, low-cost diagnostic skill taught to every medical student precisely because sound timing maps directly onto the mechanistic sequence of the cardiac cycle. Intra-aortic balloon pumps and ventricular assist devices, used in cardiogenic shock and as bridges to heart transplantation, are timed to inflate and deflate in coordination with the natural cardiac cycle to augment coronary perfusion during diastole and reduce afterload during systole. Finally, understanding how heart rate compresses diastole disproportionately explains why very rapid arrhythmias (e.g., supraventricular tachycardia) can cause inadequate ventricular filling and a collapse in cardiac output even when the heart muscle itself is structurally normal — a direct clinical consequence of the timing principles established by Wiggers nearly a century ago.
Ask the tutor: Can you walk me through how the pressure-volume loop changes shape in mitral regurgitation compared to a normal heart?
Why does the left ventricle have a much thicker wall than the right ventricle?
The left ventricle must generate enough pressure (~120 mmHg systolic) to drive blood through the entire high-resistance systemic circulation, whereas the right ventricle only needs to generate enough pressure (~25 mmHg systolic) to push blood through the low-resistance pulmonary circulation. Muscle wall thickness scales with the pressure-generating work required, similar to how a wall must be thicker to withstand higher stress. Despite this asymmetry, both ventricles eject the same stroke volume per beat because they are connected in series — any sustained imbalance would cause blood to accumulate pathologically in one circuit, as seen in conditions like right heart failure from chronic pulmonary hypertension.
What determines whether a valve is open or closed at any given moment?
Purely the direction of the pressure gradient across it. AV valves open when atrial pressure exceeds ventricular pressure (during filling) and close when ventricular pressure exceeds atrial pressure (start of systole). Semilunar valves open when ventricular pressure exceeds arterial pressure (during ejection) and close when arterial pressure exceeds ventricular pressure (start of diastole). No nerve or muscle directly operates the valve leaflets themselves; papillary muscles and chordae tendineae only prevent the AV valve leaflets from prolapsing backward under high pressure, they don't cause opening or closing.
Why is diastole longer than systole, and why does that matter at high heart rates?
At a resting rate of about 75 beats/min, one cardiac cycle lasts roughly 0.8 seconds, of which diastole occupies about 0.5 seconds and systole about 0.3 seconds. As heart rate increases, the time available for diastole shrinks disproportionately more than systole does, because the ejection phase has a relatively fixed minimum duration. At very high heart rates (e.g., during tachyarrhythmias), diastolic filling time can become so short that end-diastolic volume — and therefore stroke volume and cardiac output — falls, even though the heart is beating faster, which is why extreme tachycardia can paradoxically reduce blood flow.
How do echocardiograms use cardiac-cycle physiology to diagnose disease?
Echocardiography visualizes chamber dimensions and valve motion in real time, letting clinicians measure end-diastolic and end-systolic volumes directly and calculate stroke volume and ejection fraction, exactly per the definitions in this article. Doppler echocardiography also measures blood flow velocity across valves, from which the pressure gradient across a stenotic valve can be estimated using principles related to the flow-velocity relationship. A reduced ejection fraction points toward systolic dysfunction (weak contraction), while a high trans-valvular gradient with a small measured orifice area points toward stenosis, and abnormal backward flow signals regurgitation — all diagnoses grounded directly in cardiac-cycle mechanics.
What is the "atrial kick" and when does it matter most?
The atrial kick is the additional ventricular filling caused by active atrial contraction just before ventricular systole begins, contributing roughly 20–30% of end-diastolic volume in a healthy heart at rest. Most filling actually happens passively during the rapid-filling phase, when blood rushes in immediately after the AV valve opens. The atrial kick becomes disproportionately important when ventricular compliance is reduced (e.g., ventricular hypertrophy) or when heart rate is high and passive filling time is curtailed — which is why patients who lose organized atrial contraction, as in atrial fibrillation, can experience a meaningful drop in cardiac output despite an otherwise normal ventricle.
Why does aortic stenosis cause a systolic murmur rather than a diastolic one?
A murmur is turbulence noise, and it occurs during whichever phase of the cycle blood is trying to flow through the narrowed valve. The aortic valve is meant to be open only during ventricular ejection (systole), so turbulent flow through a stenotic aortic valve occurs specifically during systole, producing a systolic murmur heard between S1 and S2. By contrast, aortic regurgitation (a valve that doesn't close properly) produces a diastolic murmur, because the abnormal backward leak occurs during diastole when the valve should be fully closed. This is precisely why murmur timing is diagnostic of both which valve is affected and what kind of lesion it has.
How does the cardiac cycle relate to the electrocardiogram (ECG)?
The ECG records the electrical trigger for contraction, not the mechanical events themselves, but the two are tightly and predictably linked in time. The QRS complex (ventricular depolarization) immediately precedes and triggers isovolumetric contraction and the rise in ventricular pressure; the T wave (ventricular repolarization) precedes isovolumetric relaxation and the fall in ventricular pressure. This electrical-to-mechanical link — detailed further in Cardiac Action Potential & Conduction — is why the ECG trace is plotted alongside pressure and volume curves on the Wiggers diagram, letting students see exactly how many milliseconds separate electrical activation from the mechanical response it produces.