Least Count & Instrument Errors

Hand the same copper wire to three students. The first presses it against a metre rule and announces "4 mm". The second closes a vernier calipers on it and reads "4.3 mm". The third turns a screw gauge until its ratchet clicks and reports "4.27 mm". Nobody's eyesight improved — they changed instruments, and each instrument sold one more honest digit. The property being bought is the least count: the smallest change in length the device can resolve, and the single most important number on any instrument, because it decides where your measurement must stop. Boards and entrance exams treat this as core machinery, not trivia. ICSE puts least count and zero error at the front of Class 9 physics; JEE-Main's Experimental Skills unit and NEET's measurement unit recycle least-count numericals every year — "a vernier with 20 divisions spanning 19 mm…", "a screw gauge of pitch 0.5 mm…". Behind the exam questions sits the professional habit: every raw reading is uncertain by about one least count, so the least count is the entry ticket to all error analysis. Choose the wrong instrument and a beautiful five-step calculation inherits a fat, unfixable uncertainty at step zero. This module builds the framework — what least count means, how the vernier and screw tricks beat the human eye, how the least count caps significant figures, and how zero error (an instrument that lies even when measuring nothing) is caught and corrected. The two instruments get their own modules for full reading drills.

Key takeaways
  • The least count (LC) is the smallest measurement an instrument can resolve — metre rule 1 mm; standard vernier 0.1 mm; standard screw gauge 0.01 mm.
  • A raw reading is uncertain by about ±1 LC — the instrument error, present before any human mistake.
  • The vernier trick: LC=1 MSD−1 VSD\mathrm{LC} = 1\ \mathrm{MSD} - 1\ \mathrm{VSD}, a deliberate mismatch of two scales. The screw trick: LC=pitch/N\mathrm{LC} = \text{pitch}/N, rotation magnifying tiny advances.
  • Zero error — reading non-zero while measuring nothing — is systematic, corrected by signed subtraction: corrected = observed − zero error.
  • The least count fixes the last digit you may write: an instrument cannot donate significant figures it does not have.
  • Key idea: the instrument, not the experimenter, decides the precision of a raw reading — one least count is the quantum of honesty for that device.
The core insight

Every instrument has a least count — the smallest change it can resolve — and every reading from it is uncertain by about one least count, so the instrument fixes the last significant figure and the starting uncertainty of any experiment built on it.

Where this lives today

The least-count ladder never stopped climbing; only the mechanisms changed. A machinist's digital calipers resolves 0.010.01 mm with a capacitive encoder; a coordinate-measuring machine probes car parts to 1 μm1\ \mu\mathrm{m}; semiconductor fabs position wafers with interferometric stages whose "least count" is a fraction of light's wavelength. Every one ships with the two numbers a school lab would recognise: resolution (the least count) and calibrated accuracy (the promise that zero error has been hunted down). At the extreme sits LIGO, noticing its 4-km arms change by 10−1810^{-18} m — a thousandth of a proton's width — with a resolution floor set by photon shot noise (a quantum least count), systematic offsets subtracted, and random noise averaged down. Your screw gauge and a Nobel-winning detector differ in budget, not in framework.

The physical picture

Line up the three measurements. The metre rule's millimetre marks are the end of its vocabulary: the wire's edge lands between 4 and 5 mm, and your eye can vote for "about 4 mm" but cannot testify further. The vernier calipers carries a second, sliding scale that converts a between-the-marks position into a coincidence you can spot, worth a tenth of a millimetre. The screw gauge converts thickness into rotation of a finely divided thimble — half a millimetre of advance spread around a 50-division drum, each division witnessing a hundredth of a millimetre.

Figure
One wire, three instruments — each least count buys one more honest digit
The same wire, diameter close to 4.27 mm metre rule 3456 mm LC = 1 mm reads: 4 mm 1 honest digit vernier calipers coinciding line LC = 0.1 mm reads: 4.3 mm 2 honest digits screw gauge thimble, 50 divisions LC = 0.01 mm reads: 4.27 mm 3 honest digits

Notice what did not change down the ladder: the wire. What changed is the smallest step each device can distinguish — its resolution, which school physics names the least count. The metre rule resolves 1 mm; asking it for a fourth of a millimetre is asking a staircase for a position between two steps. The vernier and the screw are two mechanical answers to one engineering question — how do you resolve less than the finest division your eye can read? — the vernier by a counting trick (a second scale deliberately mis-matched to the first), the screw by a magnification trick (one full turn of a wide drum equals a tiny advance of the spindle). There is a price list: each factor of 10 in resolution costs a cleverer mechanism, a narrower range (rule: 1 m; calipers: ~15 cm; screw gauge: ~25 mm), and more ways to go wrong. The finer the instrument, the more a tiny manufacturing offset — a zero that isn't quite zero — matters. So the framework travels with its dark twin, zero error, met below.

The least-count framework

For any directly graduated scale, the least count is the value of its smallest marked division. A laboratory metre rule is graduated in millimetres:

LCrule=1 mm=0.1 cm(1)\mathrm{LC}_{\text{rule}} = 1\ \mathrm{mm} = 0.1\ \mathrm{cm} \qquad (1)

where: LC — the least count, the smallest length the instrument resolves. The rule can tell 23 mm from 24 mm; every position between collapses to a judgement call. By standard convention a raw reading therefore carries an instrument error of ±1 LC — uncertainty built in before any human carelessness. (Some texts argue ±LC/2; boards and JEE mark schemes use ±LC — the FAQ settles it.) The vernier calipers adds a sliding scale of nn divisions built so that those nn divisions span only n−1n-1 divisions of the main scale. Each vernier division is therefore slightly shorter than a main-scale division, and the shortfall is the resolution:

LCvernier=1 MSD−1 VSD=1 MSDn(2)\mathrm{LC}_{\text{vernier}} = 1\ \mathrm{MSD} - 1\ \mathrm{VSD} = \frac{1\ \mathrm{MSD}}{n} \qquad (2)

where: MSD — one main-scale division (usually 1 mm); VSD — one vernier-scale division; nn — the number of vernier divisions. With n=10n = 10 the shortfall is 0.10.1 mm; a quality n=50n = 50 instrument resolves 0.020.02 mm. The mismatch is not a defect — it is the instrument; why it lets you read to 1/n1/n of a division is the coincidence argument, derived below. The screw gauge replaces sliding with turning. Its pitch pp is the distance the spindle advances along its axis in one complete rotation, and the rotating thimble carries NN equal divisions around its rim:

LCscrew=pN(3)\mathrm{LC}_{\text{screw}} = \frac{p}{N} \qquad (3)

where: pp — pitch, typically 0.50.5 or 11 mm; NN — thimble divisions, typically 50 or 100. The standard lab gauge has p=0.5p = 0.5 mm, N=50N = 50: LC =0.5/50=0.01= 0.5/50 = 0.01 mm. The physics is leverage in reverse — a hundredth of a turn is easy to see on a centimetre-wide drum yet advances the spindle only a hundredth of half a millimetre. The screw converts invisible translation into visible rotation.

instrumenttypical least countcomfortable rangewhat it buys you
metre rule1 mm1\ \mathrm{mm}up to 1 mlengths of rods, heights, ranges
vernier calipers0.10.1 mm (lab) to 0.020.02 mmup to ~15 cmdiameters, depths, internal bores
screw gauge0.010.01 mmup to ~2.5 cmwire diameters, sheet thickness
protractor1°1°—the same idea, for angles
stopwatch (mechanical)0.10.1 s—the same idea, for time

The last two rows show least count is not about length at all — every instrument that reads divisions has one, and the ±1 LC rule follows it everywhere.

Least count caps significant figures. "4.27 mm" from a screw gauge is three significant figures because the last resolvable digit sits in the hundredths place. Write "4.273 mm" and you invented the 3; write "4 mm" and you threw away two paid-for digits. This is the operational link to the significant-figures module: the least count is where the one estimated digit of a reported measurement lives.

Derivation AWhy the vernier resolves a tenth of a division

We want to show that a vernier of nn divisions spanning n−1n-1 main-scale divisions genuinely measures to 1/n1/n of a division — not approximately, but by construction. The strategy: track how far each successive vernier line lags behind its main-scale neighbour, and show that the serial number of the coinciding line directly counts the fraction we cannot read off the main scale. Watch how a length too small to see becomes a position easy to see.

Step 1. Set up the mismatch with standard numbers: n=10n = 10 vernier divisions span 99 mm of main scale, so VSD=0.9\mathrm{VSD} = 0.9 mm and each vernier line falls short of the next main-scale line by 1−0.9=0.11 - 0.9 = 0.1 mm.

Step 2. Slide the vernier so its zero sits an unknown fraction xx past a main-scale mark. The first vernier line then sits x−0.1x - 0.1 mm past its nearest main-scale line, the second x−0.2x - 0.2 mm past its own neighbour — in general the mm-th line sits x−(0.1)mx - (0.1)m mm from a main-scale line. Why the lag grows line by line: each vernier division is 0.1 mm shorter than a main division, so the shortfalls accumulate arithmetically — the vernier is a row of rulers each losing the same tiny race.

Step 3. Coincidence is where the offset vanishes: the mm-th line aligns when x−0.1 m=0x - 0.1\,m = 0, that is when

x=m×0.1 mm=m×LCx = m \times 0.1\ \mathrm{mm} = m \times \mathrm{LC}

So the index of the coinciding line is the fraction, in units of the least count. The eye only has to judge which line matches best — a task humans do to remarkable accuracy — never to estimate a sub-division distance.

Step 4. Generalise: with nn divisions the lag per line is MSD/n\mathrm{MSD}/n, coincidence at line mm puts the vernier zero m×(MSD/n)m \times (\mathrm{MSD}/n) past the last main-scale mark, and the measurement is main-scale reading + m×LC+\, m \times \mathrm{LC}. Nothing finer than MSD/n\mathrm{MSD}/n can be distinguished — xx values between two coincidences give the same best-matching line, so the least count is a genuine resolution floor, not a style choice. Verified: with x=0.7x = 0.7 mm, the 7th line has offset 0.7−0.7=00.7 - 0.7 = 0 (coincides), while line 6 is off by +0.1+0.1 mm and line 8 by −0.1-0.1 mm — recomputed from Step 2's formula; the reading rule gives main + 7×0.17 \times 0.1 mm, matching the classic "23 mm + 7th line = 23.7 mm" example below.

Zero error: the instrument that lies at zero

Close the jaws of a calipers on nothing. It should read exactly zero — a worn, dropped, or badly made instrument often doesn't. A zero error is the reading shown when the instrument ought to show zero: the archetype of a systematic error — same amount, same direction, every measurement; immune to averaging; but measurable once and corrected forever:

corrected reading=observed reading−zero error (with sign)(4)\text{corrected reading} = \text{observed reading} - \text{zero error (with sign)} \qquad (4)

where: the zero error is positive if the instrument reads above zero on nothing (an over-reporter — subtract), negative if below (an under-reporter — subtracting a negative adds the deficit back). A gauge with zero error +0.03+0.03 mm showing 4.524.52 mm really holds 4.52−0.03=4.494.52 - 0.03 = 4.49 mm; one with −0.02-0.02 mm showing the same holds 4.52−(−0.02)=4.544.52 - (-0.02) = 4.54 mm.

Figure
Zero error is a systematic shift — measured once at closed jaws, corrected by signed subtraction
Jaws fully closed — what does the scale say? no zero error reads 0.00 positive zero error reads +0.03 mm negative zero error reads −0.02 mm Correction: corrected = observed − zero error (keep the sign) zero error +0.03 mm, observes 4.52 mm true = 4.52 − (+0.03) = 4.49 mm over-reader: subtract the excess zero error −0.02 mm, observes 4.52 mm true = 4.52 − (−0.02) = 4.54 mm under-reader: the deficit is added back

Keep the two error species separate — exams test exactly the distinction. Zero error is systematic: same size, same sign, every reading; caught by the closed-jaw check; removed by equation (4). Reading error is random: roughly ±1 LC of scatter, reduced by averaging — which never touches a systematic shift. The ICSE-practical habit: record the zero error first, then average three readings taken at different places. How the vernier's zero error is read off its coinciding line, and the screw gauge's off its thimble (plus the screw's own disease, backlash), are the business of the two instrument modules — one light preview of each reading suffices here. Vernier: main scale 23 mm, 7th of 10 divisions coincides: 23+7×0.1=23.723 + 7 \times 0.1 = 23.7 mm. Screw gauge: sleeve 5.5 mm, thimble line 24 at the datum: 5.5+24×0.01=5.745.5 + 24 \times 0.01 = 5.74 mm. Both answers stop exactly at their least count — 23.7, not 23.70; 5.74, not 5.740.

Which instrument limits the experiment?

Real experiments chain several instruments, whose least counts contribute unequally. For a product-and-power formula fractional errors add, each power multiplying its variable's contribution — so the dominant instrument is usually the one measuring the smallest quantity, not the one with the largest least count. The classic showcase, and a JEE staple, is the density of a thin wire.

Go deeper · Derivation B · 1 minThe error budget of a wire-density experiment
Derivation BThe error budget of a wire-density experiment

We want to find which of three instruments — balance, screw gauge, metre rule — controls the uncertainty in a copper wire's density, ρ=m/(πr2L)\rho = m/(\pi r^2 L). The strategy: attach ±1 LC to each measured quantity, convert to fractional errors, and add them with powers as multipliers (the propagation rule from the sibling error module). Watch the radius: it enters squared, so its fractional error counts double — and it is also the smallest length in the experiment, a double penalty.

Step 1. The measurements, each honest to its instrument: m=0.704m = 0.704 g on a milligram balance (LC 0.0010.001 g); d=0.50d = 0.50 mm by screw gauge (LC 0.010.01 mm); L=40.0L = 40.0 cm by metre rule (LC 0.10.1 cm).

Step 2. The density itself, full digits: r=0.025r = 0.025 cm, πr2=1.9635×10−3 cm2\pi r^2 = 1.9635 \times 10^{-3}\ \mathrm{cm^2}, V=1.9635×10−3×40.0=7.854×10−2 cm3V = 1.9635 \times 10^{-3} \times 40.0 = 7.854 \times 10^{-2}\ \mathrm{cm^3}, so ρ=0.704/0.07854=8.96 g/cm3\rho = 0.704 / 0.07854 = 8.96\ \mathrm{g/cm^3} — reassuringly, copper.

Step 3. Write the propagation rule for this formula. Since ρ=m π−1r−2L−1\rho = m \, \pi^{-1} r^{-2} L^{-1} and π\pi is exact,

Δρρ=Δmm+2 Δdd+ΔLL\frac{\Delta \rho}{\rho} = \frac{\Delta m}{m} + 2\,\frac{\Delta d}{d} + \frac{\Delta L}{L}

Why Δd/d\Delta d/d, not Δr/r\Delta r/r: halving dd halves its error too — fractional error is immune to exact scale factors.

Step 4. Feed in the least counts as the errors. Δm/m=0.001/0.704=0.14%\Delta m/m = 0.001/0.704 = 0.14\%. Δd/d=0.01/0.50=2.0%\Delta d/d = 0.01/0.50 = 2.0\%, doubled to 4.0%4.0\% by the square. ΔL/L=0.1/40.0=0.25%\Delta L/L = 0.1/40.0 = 0.25\%. Total: Δρ/ρ≈0.14+4.0+0.25≈4.4%\Delta\rho/\rho \approx 0.14 + 4.0 + 0.25 \approx 4.4\%.

Step 5. Read the budget like an engineer: the screw gauge — the finest instrument on the bench — contributes over 90% of the uncertainty, because it measures the smallest quantity and its error is doubled by the exponent. Upgrading the rule or balance is pointless; averaging the diameter at several places, or choosing a thicker specimen, is where all the improvement lives. Verified: 0.704/0.07854=8.963→8.96 g/cm30.704/0.07854 = 8.963 \to 8.96\ \mathrm{g/cm^3}; 0.00142+0.040+0.0025=0.0439≈4.4%0.00142 + 0.040 + 0.0025 = 0.0439 \approx 4.4\% — diameter dominates as claimed.

This derivation is the template for a whole exam family ("which measurement should be made most carefully?") and for lab design: match the instrument to the dimension so no single least count wrecks the budget — rule for the long length, screw gauge for the thin diameter.

Limiting cases

caseresultmeaning
n→∞n \to \infty vernier divisionsLC →0\to 0 on paperline thickness and eye resolution (~0.1 mm at 25 cm) become the real floor — mechanisms saturate
zero error =0= 0corrected == observedthe ideal instrument; still carries ±1 LC random reading error
object size ∼\sim LCreading is 1-2 divisions100%-level fractional error — wrong instrument for the job
repeat readings averagedrandom error shrinkszero error does NOT shrink — systematic offsets survive averaging

The last row carries the deepest lesson: precision (a small LC) and correctness (no systematic shift) are independent virtues — an instrument can have either without the other.

Worked examples

Board level — outfitting an experiment and reporting to the correct precision (ICSE pattern)

A student must measure (a) the length of a pencil close to 12 cm, (b) the diameter of its lead close to 2 mm, and (c) the thickness of its wooden body close to 7 mm. A metre rule, a vernier calipers (10 divisions spanning 9 mm) and a screw gauge (pitch 0.5 mm, 50 thimble divisions) are available. Assign instruments, state each least count, and report a consistent set of readings.

Step 1. Compute the least counts before choosing. Rule: LC =1= 1 mm. Vernier: LC =1 MSD/n=1/10=0.1= 1\,\mathrm{MSD}/n = 1/10 = 0.1 mm. Screw gauge: LC =p/N=0.5/50=0.01= p/N = 0.5/50 = 0.01 mm.

Step 2. Match instrument to dimension by fractional error. Pencil length (~120 mm) on the rule: 1/120≈0.8%1/120 \approx 0.8\% — fine. The lead (~2 mm) on the rule would carry 1/2=50%1/2 = 50\% — absurd; on the screw gauge, 0.01/2=0.5%0.01/2 = 0.5\% — assigned. The 7 mm body on the vernier: 0.1/7≈1.4%0.1/7 \approx 1.4\% — appropriate, and vernier jaws grip a diameter properly.

Step 3. Report readings that stop at each least count: length =12.1= 12.1 cm (rule), body =7.3= 7.3 mm (vernier), lead =2.07= 2.07 mm (screw gauge).

Step 4. The sentence that earns the reasoning mark: "Each measurement is uncertain by about one least count, so the finest instrument is reserved for the smallest dimension, keeping every fractional error near or below 1%." Answers: LC = 1 mm, 0.1 mm, 0.01 mm; readings 12.1 cm, 7.3 mm, 2.07 mm.

Competitive level — the dominant-error question (JEE-Main pattern)

In a simple-pendulum determination of g=4π2L/T2g = 4\pi^2 L/T^2, the length L=98.0L = 98.0 cm is measured with a metre rule (LC 0.1 cm) and the time of 20 oscillations, t=39.8t = 39.8 s, with a stopwatch (LC 0.1 s). Find the maximum percentage error in gg and the instrument that dominates it.

Step 1. Propagation rule with powers as multipliers: Δgg=ΔLL+2 ΔTT\dfrac{\Delta g}{g} = \dfrac{\Delta L}{L} + 2\,\dfrac{\Delta T}{T}. Since T=t/20T = t/20 with 20 exact, ΔT/T=Δt/t\Delta T/T = \Delta t/t — counting oscillations is a free error-divider.

Step 2. Insert the least counts: 0.198.0+2×0.139.8=0.0010+0.0050=0.0060\dfrac{0.1}{98.0} + 2 \times \dfrac{0.1}{39.8} = 0.0010 + 0.0050 = 0.0060.

Step 3. Δg/g≈0.6%\boxed{\Delta g/g \approx 0.6\%}, dominated five-to-one by the stopwatch — the time term, squared by the exponent. (The value itself: T=1.99T = 1.99 s, g=39.478×0.980/1.992=9.77 m/s2g = 39.478 \times 0.980 / 1.99^2 = 9.77\ \mathrm{m/s^2}.)

Step 4. The MCQ scan: (coarsest relative resolution) × (highest power) wins — the rule resolves 1 part in 980, the clock only 1 in 398, and the clock is squared. Timing more oscillations is the designed fix; "why time many oscillations?" is itself a standard one-mark question. Timing note: 75 seconds — 20 to write the rule, 35 for the two divisions, 20 to double, add and rank. If only the dominant source is asked, comparing 1/398 doubled against 1/980 takes 20 seconds flat.

Exam traps

Reporting digits the instrument never resolved. "12.15 cm by metre rule" is an invented hundredth — the rule stops at millimetres. End the reading at the least-count digit; boards deduct the precision mark, and JEE distractors are built from over-written digits.

Dropping the ±LC when asked for error. A single metre-rule reading is ±1 mm by convention — and a length needs the rule read at both ends, so worst-case ±2 mm; the doubling is a favourite JEE-Main twist.

Zero-error sign flips. Corrected == observed −- zero error, with its sign. Anchor: positive zero error means the instrument over-reads, so the truth is smaller.

Averaging away a systematic error. Five readings with the same uncorrected zero error average to the same wrong answer — averaging fights random scatter only.

Unit slips between mm and cm. Least counts are quoted in mm but densities want cm: convert the LC along with the reading (0.010.01 mm =0.001= 0.001 cm) — a misplaced decimal here poisons the whole error budget. And "the screw gauge is more accurate" loses the definition mark — it is more precise; accuracy depends on calibration and zero error (a direct ICSE/ISC one-liner).

Origins · 1 minWilliam Thomson and how this was discovered
WT
William Thomson
1824–1907 · Glasgow

William Thomson — Lord Kelvin from 1892 — turned precision measurement into the ideology of physics. From his Glasgow laboratory, Britain's first true teaching lab, came the mirror galvanometer that made the 1866 transatlantic telegraph readable, an absolute temperature scale anchored to thermodynamics rather than any particular thermometer, and a generation of instruments whose limits were known numbers rather than hopes. His creed — "when you can measure what you are speaking about, and express it in numbers, you know something about it" — is this module in Victorian prose: an instrument is only as honest as the smallest division it can defend.

History
1631
— Pierre Vernier publishes the sliding auxiliary scale, turning sub-division estimation into line-matching.
1638
— William Gascoigne fits a calibrated screw to a telescope eyepiece: the first micrometer measurement in science.
1866
— Thomson's mirror galvanometer reads faint transatlantic cable signals — instrument resolution as an economic force.
1960
— The SI is founded; least counts worldwide become traceable to shared standards rather than local artefacts.

Going further

Texts. NCERT Physics XI, Ch. 2 (Units and Measurement) · Concise Physics (ICSE Class 9), Ch. 1 Measurements and Experimentation · H.C. Verma, Concepts of Physics Vol. 1, Ch. 2 · JEE-Main Experimental Skills unit — vernier calipers and screw gauge are its first two named items.

Provenance. Standard instrument conventions per NCERT Ch. 2 and ICSE Class 9 practicals. A verifier should recompute: vernier LC =1/10=0.1= 1/10 = 0.1 mm, 19/20=0.95⇒19/20 = 0.95 \Rightarrow LC =0.05= 0.05 mm; screw LC =0.5/50=0.01= 0.5/50 = 0.01 mm; readings 23+7(0.1)=23.723 + 7(0.1) = 23.7 mm, 5.5+24(0.01)=5.745.5 + 24(0.01) = 5.74 mm; corrections 4.52∓0.03/0.02→4.49/4.544.52 \mp 0.03/0.02 \to 4.49/4.54 mm; density 0.704/(π×0.0252×40.0)=8.96 g/cm30.704/(\pi \times 0.025^2 \times 40.0) = 8.96\ \mathrm{g/cm^3} with budget 0.14+4.0+0.25≈4.4%0.14 + 4.0 + 0.25 \approx 4.4\%; pendulum budget 0.1/98.0+2(0.1/39.8)=0.6%0.1/98.0 + 2(0.1/39.8) = 0.6\%, g=9.77 m/s2g = 9.77\ \mathrm{m/s^2}.

Prerequisites. Accuracy, Precision & Uncertainty · Absolute, Relative & Percentage Errors. Leads to. The Vernier Calipers · The Screw Gauge · Error-Question Patterns (the technique drill). UG deep dive: the mechanics track's measurement-statistics articles.

Is the instrument error ±LC or ±LC/2? My tutor says half.

Both conventions exist; the honest answer is "state which one you use". The ±LC/2 camp says you can judge which half of a division the mark sits in; the ±LC camp answers that edge alignment, parallax and the second end of the object eat that optimism, so one full LC is the safer worst-case bound. CBSE, ICSE and JEE mark schemes use ±1 LC, as does every numerical here — and "taking instrument error = ±1 LC" costs one clause.

If zero error can be corrected exactly, why is it called an error at all?

Because it is an error of the instrument, and it stays one for everyone who does not check. The correction is exact only after you measure the zero error — itself a reading, uncertain by ±LC. Correction removes the systematic shift; the random uncertainty remains, so a corrected reading still carries ±1 LC (exams love that layering). Taxonomy is the deeper point: zero error is the textbook systematic error — repeatable, directional, immune to averaging.

Why does measuring a length with a ruler carry ±2 mm sometimes and ±1 mm other times?

Count the scale judgements needed. A single position is one judgement: ±1 LC. A length needs both ends read — two judgements — worst case ±2 LC. You dodge this by starting the object at a clean graduation (the 10.0 cm mark, not the battered zero edge), making the start essentially exact. Questions saying "both ends read against the scale" are signalling ±2 LC.

Does a bigger number of vernier divisions always mean a better instrument?

Up to a point. LC = MSD/n improves with n, and quality instruments use 20 or 50 divisions. But physical floors intervene: engraved lines have thickness (~0.1 mm), the eye resolves about 0.1 mm at reading distance, and machining tolerance must be far finer than the claimed LC. Beyond n ≈ 50 on a millimetre scale, coincidence judgement becomes guesswork and the printed LC is marketing. That is exactly why the next factor of 10 is bought with a different mechanism — the screw — not a denser vernier.

How do I choose which instrument to name in a "which would you use" question?

Estimate the fractional error each instrument would leave — LC over the size measured, aiming for about 1% or below. Wire (~0.5 mm): only the screw gauge (2%) is defensible. Coin (~2 mm): screw gauge or fine vernier. Pencil (~120 mm): the rule's 0.8% is fine — and vernier jaws cannot open that far anyway. Mention range as well as least count; the marker wants exactly that pairing.

My digital calipers shows 4.27 mm directly — does least count still apply?

Completely. The display's last digit is the least count (0.01 mm): electronics quantise position into steps just as engraved lines do, and the reading is uncertain by about one step. Digital instruments still have zero error — the ZERO button is the closed-jaw check, automated. The display removes only the human coincidence-judging (and its parallax); resolution floor plus systematic offset transfers unchanged.