Newton's Law of Cooling
Pour a cup of coffee at 90 °C and walk away. Ten minutes later it has shed a scalding 25 degrees. Ten minutes after that it has fallen only about fifteen more. The next ten buy you barely nine. The coffee is not running out of heat — it is running out of reason to lose heat. Every hot body cools fastest when it is furthest from room temperature, and slows as it closes the gap. That single sentence is the whole of Newton's law of cooling, and it earns marks in every board that touches heat transfer: a CBSE statement question, an ICSE lab experiment, a JEE-Advanced two-interval numerical, a NEET assertion-reason about the temperature excess. The law says something sharper than "hot things cool." It says the rate of cooling is proportional to the excess temperature — how far the body sits above its surroundings — and not to its temperature at all. A body at 80 °C in a 20 °C room cools twice as fast as the same body at 50 °C in the same room, because its excess (60 K) is twice as large (30 K). Feed that in and out comes an exponential: a steep plunge that bends over and glides onto the room's temperature, never quite arriving, never overshooting. You need no calculus for any of it. Two calculus-free tools — the average-temperature method and recognising the exponential shape — settle every cooling problem a school or entrance paper can set.
- Newton's law of cooling: a body's rate of cooling is proportional to its temperature excess over the surroundings, — not to its temperature itself.
- In symbols, , which reads in plain words as "degrees lost per minute constant excess." The minus sign only says the temperature is falling.
- The result you use is the exponential : the excess shrinks by the same fraction in every equal interval, so equal intervals give ever-smaller drops.
- The calculus-free board tool is the average-temperature method: over a small drop, cooling rate (mean temperature of the interval ) — one line of arithmetic.
- This is a small-excess law — the straight-line approximation to the radiation law. It fits a warm cup and fails badly for a red-hot poker.
- Key idea: cooling rate tracks the excess over the surroundings, so the excess decays exponentially — halving in a fixed time, no matter where you start.
A body loses heat at a rate proportional to how far its temperature sits above its surroundings, so its excess temperature decays exponentially — fast at first, ever more slowly as it nears ambient, and never below it.
Where this lives today
Forensic science estimates time of death this way. A body starts near 37 °C and cools towards the room. If the room is at 20 °C and the corpse is found at 30 °C, then with a cooling constant measured for the conditions, equation (3a) inverts to hours since death. Pathologists correct for clothing, body mass and airflow — all adjustments to , , and inside .
Electronics and engines are designed around the same equation: a CPU heat sink maximises and, with its fan, , pushing up so the chip settles at a safe temperature. Food-safety rules are cooling rules — hot food must cross the bacterial danger zone fast, so kitchens divide a stockpot into shallow trays, multiplying and therefore . And the school cooling-curve experiment remains one of the cleanest demonstrations that a real system obeys an exponential law.
The physical picture
Put a hot metal block in a cool room. Heat leaks from its surface by three routes at once: conduction into whatever it touches, convection as the neighbouring air warms, thins and floats away, and thermal radiation streaming off as infrared. Every one of those routes is driven by the difference between block and surroundings. Nothing here depends on the block's temperature in isolation: a block at 300 °C in a 290 °C oven barely cools at all, while a block at 30 °C on a −10 °C night bleeds heat steadily. What matters is the excess, . Now watch that unfold in time. At the start the excess is large, so heat pours out and the temperature plunges. But every degree lost shrinks the excess, a smaller excess means a slower leak, and so the next degree takes longer to lose. The body throttles its own cooling. That feedback — the driver of a process being consumed by the process itself — is the standard recipe for exponential decay, the same shape as a discharging capacitor or a decaying nucleus. The curve dives, bends over, and settles onto the line like a plane easing onto a runway.
Read that figure once and the topic is yours. The first ten minutes cost the coffee 25 °C, the next ten only 15.4 °C, the next only 9.5 °C — and each drop is 0.615 times the one before, the same ratio every time. A constant ratio per fixed interval is the fingerprint of an exponential, and it is what separates the student who understands cooling from the one who assumes (wrongly, and expensively) that a body losing 25 °C in the first ten minutes must lose another 25 °C in the next.
The law in words, then in symbols
Newton's statement, for a body at temperature in surroundings held at :
where: — the body's temperature at some instant; — the constant temperature of the surroundings (some textbooks write ); — the temperature excess, the only quantity the law cares about; — the cooling constant, in or , a property of this body in this environment, not of the material alone; — the rate at which the temperature changes. The minus sign is bookkeeping: a hotter body has a positive excess, so comes out negative — the temperature is falling. You do not need calculus to read equation (1). In words: the number of degrees lost per minute is proportional to how many degrees the body stands above the room. Pictorially, is the slope of the tangent to the cooling curve — steep at the start, shallow at the end — and the law says that slope is always the same fixed multiple of the vertical gap between curve and ambient line. For working problems, boards use the finite-difference form. Take a small drop from to in a time . The average cooling rate over that window is , and the excess to pair with it is that of the mean temperature of the interval:
where: , — the temperatures at the start and end of the interval; — the time taken; — the mean temperature, standing in for the body's steadily changing ; — the same cooling constant. The physical reading: across a small window the body is always somewhere between and , so the honest number to represent it is the middle one. Equation (2) is the average-temperature method — pure algebra, no calculus — and CBSE, ICSE, NEET and JEE numericals are built on it. Its one condition: the drop must be small compared with the excess.
The exponential — a result to use, not to derive
Feed equation (1) into the machinery of calculus and out comes a formula for the temperature at any time. That solving step belongs to a later course; the answer belongs to you now, because boards quote it and competitive papers expect you to wield it:
where: — the body's temperature at ; — the initial excess; ; — the cooling constant of equation (1); — the temperature after a time . Read the structure, not the symbols: the excess starts at and is multiplied by the shrinking factor . Rearranged, that is the sentence worth memorising:
The excess decays exponentially; everything else is decoration. Two consequences follow, and both are exam questions in disguise.
Equal times give equal fractions. In any fixed interval the excess is multiplied by — the same factor wherever you start. Our coffee's excess is multiplied by every ten minutes. From an initial excess of : after 10 min it is (temperature 65 °C), after 20 min (49.6 °C), after 30 min (40.1 °C). The absolute drops shrink — 25.0, then 15.4, then 9.5 °C — while the fraction stays locked at 0.615. Any "cools from A to B in minutes; find the temperature after another minutes" question tests this and nothing else. It also means the excess has a half-life, min, and a time constant min in which it falls to of its value.
The body never reaches ambient, and never dips below it. As grows, shrinks towards zero but is never zero, so creeps onto and stops. Cooling cannot overshoot: at the excess is zero, so by equation (1) the rate is zero. That is thermal equilibrium, and it is why the curve flattens instead of crossing.
The lab experiment — and the straight line that tests the law
The school experiment is simple: fill a calorimeter with hot water and record its temperature each minute as it cools. Plotting against gives the falling curve of the first figure — pretty, but not proof, since many curves fall like that. The proof comes from replotting. Take successive pairs of readings, compute the cooling rate for each, and plot it against the excess of the mean temperature, . Newton's law predicts equation (2): a straight line through the origin, of slope . That is the graph that earns the marks.
Three marks hide in that graph. The line must pass through the origin, because zero excess means zero cooling — a best-fit line with an intercept means your is wrong. The slope is : a rate of at an excess of gives , so at an excess of the same body must cool at . And the real points bend above the line at large excess (the red dashed curve), because a body far above ambient loses a disproportionate share by radiation, which follows rather than the excess — precisely what Dulong and Petit found in 1817.
Our goal is a working method for the commonest cooling question in the syllabus: a body cools from one temperature to another in a known time, and we must find how long the next stretch of cooling takes. Equation (1) contains a rate of change, which looks like calculus; the point here is that over a small drop you may replace that instantaneous rate by an honest average, replace the changing temperature by the mean of the interval, and reduce the whole problem to a ratio you can do in your head. We build the tool on the classic anchor: a body cools from 80 °C to 70 °C in 5 minutes in surroundings at 20 °C, and we want the time to cool from 70 °C to 60 °C.
Step 1. Set up both intervals. The body falls , a drop of , in min, so its average cooling rate is . During that window it was never exactly at 80 nor at 70 but always between, so the fair representative temperature is the mean, , whose excess is . The second interval, , is another drop in an unknown time , at an average rate , with mean temperature and excess .
Step 2. Apply equation (2) to each. The same body in the same room shares one , so and . Two equations with a common — so divide one by the other and never need at all. That cancellation is why the method is so fast under exam pressure.
Step 3. Take the ratio: , so . The body is cooling more slowly now, exactly as the physical picture demands, because it has closed part of the gap to the room.
Step 4. Turn the rate back into a time. The second drop is again , so (6.11 min to three figures). Sense-check: the answer must exceed 5 minutes, because the excess driving the cooling is now smaller. If your arithmetic returns a shorter second interval, you have inverted the ratio — flip it and move on. If itself is wanted, .
Step 5. Be honest about the price. The method assumes the rate over each window is well represented by the mean temperature — fair when the drop () is small beside the excess (). Solve the same problem exactly with equation (3a) and you get , then min against the shortcut's min — agreement to . For small drops the shortcut is very nearly exact, and it is the answer the marking scheme wants. Verified: the rate ratio, min, and the exact-exponential cross-check (, min) are recomputed in verify_hs2-newtons-law-of-cooling.py.
Why the law is linear — and exactly when it breaks
Newton's law is not fundamental but an approximation, and knowing which approximation is what lifts an answer into the top band. A hot body loses heat two main ways. Convection genuinely is close to linear in the excess: the surface sheds power , where is the convective heat-transfer coefficient (– in still air, far more with a fan). That escaping power drains a store of heat capacity , so the temperature falls at — which identifies the cooling constant itself:
where: — the surface coefficient, set by airflow and surface; — the exposed area; — the mass; — the specific heat capacity. Read it as a contest between losing (the numerator, all surface) and storing (the denominator, all bulk): a thin sheet or a droplet has a large and cools in moments, a bathtub has a tiny and stays warm for hours. It also settles every "which body cools faster" MCQ, and it shows why is a property of the whole set-up rather than of the material.
Radiation, the second route, is emphatically not linear. The Stefan–Boltzmann law gives the net radiated power as
where: — emissivity (0 to 1); — the Stefan–Boltzmann constant; — surface area; , — the absolute temperatures of body and surroundings, in kelvin. That fourth power is ferocious and looks nothing like a straight line in the excess. Yet for a small excess it flattens into one — and that is the deep reason Newton's law exists at all.
Go deeper · Derivation B · 1 minNewton's linear law is the small-excess limit of the T⁴ radiation law
Our goal is to show that the linear law you have just learned is not a rival to the Stefan–Boltzmann law of the radiation chapter but its near neighbour: when the temperature excess is small compared with the absolute temperature of the surroundings, the fourth-power law bends into a straight line whose slope is fixed by . That one insight explains why the law fits a cup of tea, why it collapses for a glowing poker, and why the cooling constant depends on the room as well as on the body. The only tool needed is the binomial expansion.
Step 1. Write the excess as , so , and put it into equation (5): . The quantity is the fractional excess, and in everyday cooling it is small — tea at in a room has and , so . Expand: , and for small everything beyond is negligible, so — proportional to the excess, a straight line, precisely Newton's law, with the constants swept into the slope . Dividing by gives : equation (4) again, with an effective . Radiation masquerades as a linear surface loss whenever the excess is small.
Step 2. Test the approximation, since this is where the physics lives. Take . For a excess () the exact bracket is while the linear estimate — low by about . For a excess () the exact bracket is against a linear — now low by , a catastrophe. Hence the rule to quote in an exam: Newton's law holds when in kelvin. Warm water, coffee, a calorimeter, a human body — fine. A red-hot poker at in a room — hopeless; that needs the full law, the business of the cooling-and-radiation numericals archetype. Verified: the binomial coefficient 4, the exact-versus-linear brackets at and excess, and the resulting and shortfalls, recomputed in verify_hs2-newtons-law-of-cooling.py.
Limiting cases
| Case | Result | Meaning |
|---|---|---|
| (zero excess) | rate of cooling | thermal equilibrium — which is why the rate-versus-excess line passes through the origin |
| from above, asymptotically | the exponential never reaches zero, so the body never quite attains ambient and can never overshoot below it | |
| large excess | fast cooling, steep tangent | the coffee sheds at the start but only after 40 minutes |
| large (thin body, big surface, forced air) | cools quickly; small | — blow on your soup and you raise ; a thin wire has an enormous and cools at once |
| excess comparable with in kelvin | law fails — use | a red-hot body radiates far more than the linear law allows, and the lab points curve upward |
Worked examples
Board level — the next ten minutes of cooling (CBSE/ICSE/NEET pattern)
A body cools from to in 10 minutes. The surroundings are at . What is its temperature after the next 10 minutes?
Step 1. First interval, by equation (2): the drop is in 10 min, so the rate is ; the mean temperature is , so the excess is .
Step 2. Hence , giving .
Step 3. Second interval, with the unknown final temperature : the rate is and the mean temperature is , so equation (2) reads .
Step 4. Multiply through by 30: , and the cancels the on the right, leaving .
Step 5. Solve: , so (quoted in many keys as ). Sense-check: the second drop is , smaller than the first drop of , exactly as a shrinking excess demands. The candidate who assumes a second drop and writes loses the whole mark — and that is the commonest wrong answer in the topic.
Competitive level — coffee, an exponential and a clock (JEE-Main/JEE-Advanced pattern)
Coffee at stands in a room at and cools to in 10 minutes. Find (a) the cooling constant, (b) the temperature 20 minutes after the start, and (c) when the coffee reaches a drinkable .
Step 1. Work in excesses, never raw temperatures — that is the whole trick. Initial excess ; excess after 10 min .
Step 2. Equation (3a) gives , so and . Writing as rather than saves you from a stray minus sign.
Step 3. Part (b) needs no exponential at all. Every 10-minute window multiplies the excess by the same , so after 20 min the excess is and the temperature is . The long route, , returns the identical — but the fractional route needs no calculator.
Step 4. Part (c): invert equation (3a). The target excess is , so and . Timing note: about two minutes for all three parts. The exam-winning move is Step 3 — spotting that "another 10 minutes" means "multiply the excess by the same factor again" converts a logarithm into a single multiplication. The classic wasted minute is converting to kelvin: don't. Every temperature here sits inside a difference, and a difference is numerically identical on both scales.
Competitive level — find the temperature of the room (JEE-Advanced/NEET pattern)
A body cools from to in 5 minutes, and from to in the next 5 minutes. Find the temperature of the surroundings.
Step 1. Recognise the type: two intervals, equal times, unequal drops, and the unknown is itself — so must remain a symbol, , inside every excess.
Step 2. First interval: drop in 5 min, so rate; mean temperature ; excess .
Step 3. Second interval: drop in 5 min, so rate; mean temperature ; excess .
Step 4. Divide equation (2) for the first interval by equation (2) for the second, and cancels: , i.e. . Cross-multiplying, , so and .
Step 5. Cross-check with the exponential — this problem is a beautiful special case. With the three excesses are , and , and while too. Equal fractional drops in equal times: the exponential signature, satisfied exactly, so both methods agree perfectly on . They differ only on — the ratio method gives , the exponential , a gap invisible in any exam. Timing note: ninety seconds. Everything hinges on Step 4 — divide the two equations so vanishes. A student who instead writes two exponentials and takes logs burns four minutes to reach the same . Note too what makes the problem solvable: the drops in equal times are unequal, and their ratio is what pins down .
Exam traps
Using the temperature instead of the excess. Every bracket in this topic is . NEET assertion-reason questions bait exactly this: "a body at 60 °C always cools at the same rate" is false, because the rate depends on the room it sits in. If is given, it appears in your working.
Assuming equal drops in equal times. Cooling is exponential: equal intervals give equal fractions, not equal amounts. A body falling 60 → 50 °C in ten minutes does not reach 40 °C in the next ten — it reaches 42.9 °C. This is the most-marked error in CBSE and ICSE papers.
Using the starting temperature in the average-temperature method. Equation (2) needs the excess of the mean of the interval, , not . Writing instead of corrupts every number that follows.
Applying the law at large excess. It is the small-excess linearisation of — good to about 5% for a 10 K excess above a 300 K room, wrong by 38% at 100 K. JEE-Advanced punishes this: a glowing body needs Stefan, not Newton. (Note the kelvin rule too: differences may stay in °C, but the moment you use , absolute kelvin is compulsory.)
Which board wants what. NCERT Class 11 and the published JEE-Advanced syllabus keep Newton's law of cooling by name, and it is standard in ICSE, CBSE, NEET and A-Level. One wrinkle: the 2024 NTA rationalisation dropped the literal phrase from the JEE-Main syllabus PDF, though heat transfer remains in Unit 7. Coaching material and previous-year JEE-Main papers still use it freely, so learn it regardless.
Origins · 1 minIsaac Newton and how this was discovered
The Newton of the Principia needs no introduction; the Newton of this article is a less familiar figure — the patient experimental thermometrist. In 1701, while Master of the Mint, he published a short paper in the Philosophical Transactions titled Scala graduum caloris ("A scale of the degrees of heat") — and published it anonymously. In it he calibrated a linseed-oil thermometer against fixed points, then faced the problem of measuring temperatures far too hot for any thermometer: molten metals, red-hot iron. His solution was to let a heated iron block cool in a steady draught of air, assuming its rate of cooling was proportional to its excess of heat over the surrounding air — an assumption he checked against his data, and which let him extrapolate his scale far beyond its range. The cooling law was born not as a theory but as an instrument-maker's tool.
Going further
Texts. NCERT Physics Class 11, Ch. 11 (Thermal Properties of Matter) — the statement, the exponential and the standard two-interval numericals · ISC/ICSE Concise Physics, Heat — the calorimeter cooling-curve experiment · H. C. Verma, Concepts of Physics Vol. 2, Heat Transfer.
Provenance. Standard results; every number is recomputed in the verifier — the average-temperature anchor ( min, ) and its exact-exponential cross-check (, min); the coffee exponential (, , , min to 40 °C, min, min, factor , drops 25.0/15.4/9.5 °C, rates 3.2 and 0.45 °C/min); the board answer ; ( vs ); the lab slope and at excess 24 °C; the estimate ; the linearisation errors (5% at 10 K, 38% at 100 K); the forensic 5.3 h.
Prerequisites. Conduction & Thermal Conductivity · Thermal Radiation & the Black Body. Leads to. ARCHETYPE: Cooling & Radiation Numericals (where the full machinery takes over). Siblings. Convection (the origin of ) · Stefan–Boltzmann & Wien's Laws (the exact law this one approximates). Go deeper (UG). "Stefan-Boltzmann Law and Radiation Pressure" treats the radiation side exactly, and "Transport Coefficients and Green–Kubo Relations" explains where a coefficient like comes from microscopically — enrichment pointers only.
Why does the law use the excess T − T s rather than the body's temperature?
Because heat flows only when there is a temperature difference. Conduction, convection and net radiation are all driven by the gap between body and surroundings — close the gap and every one of them shuts off. A body at 60 °C in a 20 °C room cools four times faster than the same body at 60 °C in a 50 °C room, because the excess is 40 °C in one case and 10 °C in the other. A law written in terms of alone could not tell those situations apart, and would absurdly predict cooling even when body and room are at the same temperature.
Do I need to convert temperatures to kelvin?
For Newton's law of cooling, no. Every temperature appears inside a difference — , or a drop — and a difference is numerically identical in °C and K, because the offset cancels on subtraction. So , and that same is the excess in kelvin. Cross to the Stefan–Boltzmann law, however, and kelvin is compulsory: is not a difference, and using °C there gives nonsense. One law forgives you; the other does not.
Do I need calculus to solve cooling problems?
No. The form is only a compact way of writing "degrees lost per minute is proportional to the excess". Two calculus-free tools cover everything. If the question gives drops over intervals, use the average-temperature method of equation (2): the rate over an interval equals times the excess of that interval's mean temperature. If it asks for a temperature at a given time, substitute into . Neither route requires you to integrate anything.
Is the average-temperature method exact, or am I cheating?
It is an approximation — but an unusually good one. It replaces the body's continuously changing temperature over an interval by the mean of the endpoints, which is fair when the drop is small compared with the excess. Test it on the classic anchor: a body cooling 80 → 70 °C in 5 minutes with surroundings at 20 °C. The average-temperature method predicts 6.11 minutes for the next 10 °C; the exact exponential gives 6.12 minutes — a gap of , far below any exam tolerance. It is also the method every board marking scheme expects.
Does the same law describe a cold body warming up?
Yes, and that is a satisfying check on it. Put a fridge-cold drink at 5 °C into a 25 °C room. The excess is now negative, so equation (1) makes positive — the temperature rises. The drink warms fast at first, then ever more slowly, approaching 25 °C along the identical exponential, mirrored. Nothing in the law prefers cooling to heating: it drives any body towards equilibrium, and the further away it is, the harder it is driven.
Why do two identical cups of coffee cool at different rates?
Because depends on the whole arrangement, not just on the coffee. A wide shallow mug exposes a bigger surface than a tall narrow one holding the same mass, so it has a larger and cools faster — which is why a saucer is the traditional way to cool tea in a hurry. Stirring or blowing raises ; a lid slashes both and the effective ; a vacuum flask attacks all three transfer routes at once.