Induction motor equivalent circuit

An induction motor's stator winding couples to its rotor winding magnetically, exactly the way a transformer's primary couples to its secondary — so it is no accident that the per-phase equivalent circuit of an induction motor looks like a transformer equivalent circuit with stator resistance R1R_1, leakage reactance X1X_1, and a magnetising branch drawing the exciting current. The one genuinely new feature sits in the rotor branch: because the rotor spins at slip ss, its induced EMF and frequency both scale with ss, and referring this spinning rotor circuit back to the stationary stator frequency collapses everything into a single, elegant term — the slip-dependent resistance R2′/sR_2'/s. That one fraction is the whole story of how an induction motor breathes electrically. It tells you why starting current is huge, why current falls as the motor speeds up toward synchronous speed, and — split into two pieces — exactly how much of the rotor's electrical power is wasted as heat and how much comes out as usable shaft power. This article builds that circuit, derives the R2′/sR_2'/s split algebraically, and works through the numbers for a real slip value.

The core insight

Referring the induction motor's slip-dependent, rotating rotor circuit to the stationary stator collapses the rotor resistance and slip into one term, R2′/s=R2′+R2′(1−s)/sR_2'/s = R_2' + R_2'(1-s)/s, where R2′R_2' dissipates rotor copper loss and the remainder represents the mechanical power developed.

The core idea

The stator supplies the magnetomotive force that sets up the air-gap flux, and this flux links the rotor exactly as a transformer's primary flux links its secondary. So three of the four elements in the induction motor's per-phase equivalent circuit are transformer elements, referred to the stator side by the effective turns ratio:

  • R1,X1R_1, X_1 — stator winding resistance and leakage reactance, in series with the supply.
  • R0,X0R_0, X_0 (equivalently G0,B0G_0, B_0) — the magnetising branch, shunted across the supply, carrying the exciting current that sets up the mutual flux and accounts for core loss.
  • R2′,X2′R_2', X_2' — rotor resistance and leakage reactance, referred to the stator.

The rotor branch is where the transformer analogy breaks. A cage rotor is short-circuited on itself (or, for a wound rotor, closed through external resistance) and turns at slip ss, so its induced EMF and frequency are both ss times the stator's. Referring this rotor circuit to the stator at the supply frequency turns the plain resistance R2′R_2' into the slip-dependent term:

R2′s=R2′+R2′(1−ss)\frac{R_2'}{s} = R_2' + R_2'\left(\frac{1-s}{s}\right)

where: R2′R_2' is the stator-referred rotor resistance (ohms), ss is the slip (dimensionless, between 0 and 1 for motoring), and R2′/sR_2'/s is the effective resistance that the stator-referred rotor current I2′I_2' sees in the equivalent circuit, drawn as R2′R_2' in series with jX2′jX_2' and this variable resistance. The split on the right matters physically. The R2′R_2' term is real rotor copper loss — heat, always present. The extra term R2′(1−s)/sR_2'(1-s)/s is not a physical resistor; it is a bookkeeping resistance across which the gross mechanical power developed appears, electrically, in the circuit model. As s→0s \to 0 (near synchronous speed, light load), R2′/s→∞R_2'/s \to \infty and rotor current shrinks toward zero. As s→1s \to 1 (standstill), R2′/sR_2'/s falls to its minimum, R2′R_2' itself, so rotor — and hence stator — current is largest. This is exactly the physical picture of a large starting current that tapers off as the motor runs up to speed.

Figure
Per phase equivalent circuit of an induction motor showing stator resistance and reactance the magnetising branch and the rotor branch split into rotor resistance and the mechanical power resistance
Per-phase equivalent circuit, referred to the stator V R1 jX1 R0,X0 magnetising R2' jX2' R2'(1-s)/s mechanical power copper loss

Common traps

  • Treating the induction motor equivalent circuit as identical to a transformer's — the stator impedance and magnetising branch are analogous, but the slip-dependent R2′/sR_2'/s has no counterpart in a static transformer.
  • Forgetting that R2′/sR_2'/s already includes R2′R_2' inside it; do not add R2′R_2' again on top of R2′/sR_2'/s when computing total rotor-branch resistance.
  • Assuming the referral of rotor quantities to the stator is automatic — it uses an effective turns ratio, treated at an introductory level here without full derivation.
  • Ignoring the magnetising branch when estimating stator current at low slip — the exciting current is not negligible compared with the shrinking load component of current near synchronous speed.
Derivation ASplitting R2'/s into copper loss and mechanical power

The goal is to show algebraically, starting only from the stator-referred rotor branch R2′/sR_2'/s in series with jX2′jX_2', why this single fraction can be rewritten as an actual resistor R2′R_2' (rotor copper loss) plus an extra term R2′(1−s)/sR_2'(1-s)/s that stands in for the mechanical power delivered to the shaft — the split that makes the equivalent circuit useful for computing motor performance rather than just current.

Step 1. Start from the referred rotor-branch resistance as it appears in the circuit, R2′/sR_2'/s, where 0<s≤10 < s \le 1 for a motor running below synchronous speed. Write it as a single fraction with numerator R2′R_2': no algebra has happened yet, this is just the quantity we want to decompose.

Step 2. Add and subtract R2′R_2' inside the fraction. R2′s=R2′−sR2′+sR2′s=sR2′s+R2′−sR2′s\dfrac{R_2'}{s} = \dfrac{R_2' - sR_2' + sR_2'}{s} = \dfrac{sR_2'}{s} + \dfrac{R_2' - sR_2'}{s}. The first piece simplifies immediately to R2′R_2'; the second is R2′(1−s)s\dfrac{R_2'(1-s)}{s}.

Step 3. Collect the result: R2′s=R2′+R2′(1−ss)\dfrac{R_2'}{s} = R_2' + R_2'\left(\dfrac{1-s}{s}\right). The circuit is now equivalent to R2′R_2' in series with a second resistor of value R2′(1−s)/sR_2'(1-s)/s, both carrying the same stator-referred rotor current I2′I_2'.

Step 4. Interpret each term physically. The power I2′2R2′I_2'^2R_2' dissipated in the first resistor is genuine rotor copper loss — heat in the rotor conductors, unavoidable. The power I2′2R2′(1−s)/sI_2'^2R_2'(1-s)/s dissipated in the second, fictitious resistor is not heat anywhere; in the equivalent circuit's bookkeeping it stands for the gross mechanical power converted to shaft output, because it vanishes exactly when s=1s=1 (standstill, no shaft power) and grows without bound as s→0s\to0 (no torque needed to just spin at synchronous speed, in the ideal case). Check: at s=1s=1, R2′(1−s)/s=0R_2'(1-s)/s = 0, so all rotor-branch power is copper loss — consistent with a stalled motor developing zero mechanical output. At s→0s\to0, R2′/s→∞R_2'/s\to\infty, so current (and hence both loss terms) shrinks toward zero even though the resistor R2′(1−s)/sR_2'(1-s)/s itself grows — the circuit self-consistently predicts small current near synchronous speed.

Worked example

Problem. A three-phase induction motor has a stator-referred rotor resistance R2′=0.4 ΩR_2' = 0.4\ \Omega per phase and stator-referred rotor current I2′=20 AI_2' = 20\ \text{A} per phase at full load, where the slip is s=0.04s = 0.04. Find (a) the effective rotor-branch resistance R2′/sR_2'/s, (b) its split into copper-loss and mechanical-power terms, and (c) the rotor copper loss and mechanical power developed per phase.

Step 1. Compute the effective rotor-branch resistance at s=0.04s = 0.04: R2′/s=0.4/0.04=10 ΩR_2'/s = 0.4/0.04 = 10\ \Omega. Compare with standstill (s=1s=1), where R2′/s=0.4 ΩR_2'/s = 0.4\ \Omega — twenty-five times smaller, which is why standstill current is so much larger than full-load current.

Step 2. Split 10 Ω10\ \Omega using the derivation above: R2′(1−ss)=0.4(1−0.040.04)=0.4×24=9.6 ΩR_2'\left(\dfrac{1-s}{s}\right) = 0.4\left(\dfrac{1-0.04}{0.04}\right) = 0.4\times24 = 9.6\ \Omega. Check: R2′+9.6=0.4+9.6=10 Ω=R2′/sR_2' + 9.6 = 0.4+9.6 = 10\ \Omega = R_2'/s, consistent.

Step 3. Rotor copper loss per phase, dissipated in R2′R_2' alone: Pcu,2=I2′2R2′=202×0.4=400×0.4=160 WP_{cu,2} = I_2'^2R_2' = 20^2\times0.4 = 400\times0.4 = 160\ \text{W}.

Step 4. Mechanical power developed per phase, dissipated (in the model) in the 9.6 Ω9.6\ \Omega term: Pmech=I2′2×9.6=400×9.6=3840 WP_{mech} = I_2'^2\times9.6 = 400\times9.6 = 3840\ \text{W}.

Answer: R2′/s=10 ΩR_2'/s = 10\ \Omega at full load, splitting into 0.4 Ω0.4\ \Omega (copper loss) and 9.6 Ω9.6\ \Omega (mechanical power); the corresponding powers per phase are Pcu,2=160 WP_{cu,2} = 160\ \text{W} and Pmech=3840 WP_{mech} = 3840\ \text{W} (multiply by 3 for the total three-phase values).

Competitive stretch

If instead I2′=20 AI_2' = 20\ \text{A} and R2′=0.5 ΩR_2' = 0.5\ \Omega at s=0.05s = 0.05, the same method gives R2′/s=0.5/0.05=10 ΩR_2'/s = 0.5/0.05 = 10\ \Omega, split as R2′=0.5 ΩR_2' = 0.5\ \Omega and R2′(1−s)/s=0.5×19=9.5 ΩR_2'(1-s)/s = 0.5\times19 = 9.5\ \Omega. The powers per phase are Pcu,2=202×0.5=200 WP_{cu,2} = 20^2\times0.5 = 200\ \text{W} and Pmech=202×9.5=3800 WP_{mech} = 20^2\times9.5 = 3800\ \text{W}. Notice how sensitive PmechP_{mech} is to slip even for a small change in R2′R_2' — always recompute R2′/sR_2'/s freshly for the given slip rather than reusing a value from a different operating point.

Ask the tutor: if the R2 prime over s split feels abstract, ask the AI tutor to walk through the algebra step by step for a slip value of your choosing.

Why does the induction motor equivalent circuit look so much like a transformer's?

Because the physical coupling is the same kind: the stator winding sets up a mutual flux exactly as a transformer primary does, and the rotor winding has EMF induced in it exactly as a transformer secondary does. So the stator resistance and leakage reactance R1,X1R_1,X_1, and the magnetising branch R0,X0R_0,X_0 (or G0,B0G_0,B_0), carry over unchanged in form. The one place the analogy fails is the rotor branch, because the rotor is not stationary — it turns at slip ss, so its induced quantities are frequency-scaled by ss before being referred to the stator, giving the extra R2′/sR_2'/s term that a transformer never needs.

If R2 prime over s already includes R2 prime, why do textbooks draw the circuit with two separate resistors R2 prime and R2 prime times 1 minus s over s in series?

Both drawings represent the exact same total resistance, R2′/sR_2'/s, so the current I2′I_2' computed from the circuit is identical either way. The two-resistor version is drawn purely so you can read off the power split directly: the power in the plain R2′R_2' resistor is real rotor copper loss (heat), while the power in the extra R2′(1−s)/sR_2'(1-s)/s resistor is the model's way of representing gross mechanical power developed. If you only need stator or rotor current, the single lumped R2′/sR_2'/s is enough; if you need to separate loss from mechanical output, use the two-resistor split.

Do I need to derive the rotor-to-stator turns ratio referral from scratch for this topic?

No — at this introductory level the course expects you to use the per-phase equivalent circuit with R2′,X2′R_2', X_2' already given as stator-referred quantities, not to re-derive the referral algebra from the rotor's actual turns ratio and frequency. Know that the referral exists, is analogous to referring a transformer secondary impedance to its primary, and produces the R2′/sR_2'/s term when slip is folded in. The exhaustive derivation of the referral itself is treated lightly in this syllabus.